Phase unwrapping in the three-point Dixon method for fat suppression MR imaging.

J Szumowski, WR Coshow, F Li, SF Quinn - Radiology, 1994 - pubs.rsna.org
PURPOSE: TO present an algorithm for performing phase unwrapping for fat and water
signal separation in the three-point Dixon (3PD) method of magnetic resonance (MR) …

Double‐echo three‐point‐Dixon method for fat suppression MRI

J Szumowski, W Coshow, F Li… - Magnetic resonance …, 1995 - Wiley Online Library
A double‐echo two‐excitation pulse sequence encoding fat and water signals for a phase‐
sensitive three‐point Dixon‐type analysis (DE‐3PD) was developed and implemented on a …

Two‐point Dixon technique for water‐fat signal decomposition with B0 inhomogeneity correction

BD Coombs, J Szumowski… - Magnetic resonance in …, 1997 - Wiley Online Library
To separate water and lipid resonance signals by phase‐sensitive MRI, a two‐point Dixon
(2PD) reconstruction is presented in which phase‐unwrapping is used to obtain an …

Chemical shift-based true water and fat images: regional phase correction of modified spin-echo MR images.

JA Borrello, TL Chenevert, CR Meyer, AM Aisen… - Radiology, 1987 - pubs.rsna.org
The process of separating water and fat signal in magnetic resonance images with the Dixon
pulse sequence is hindered by phase errors in the water-fat opposed image. These errors …

Separation of fat and water in fast spin‐echo MR imaging with the three‐point Dixon technique

PA Hardy, RS Hinks, JA Tkach - Journal of Magnetic …, 1995 - Wiley Online Library
A method for suppressing fat in fast spin‐echo imaging with the three‐point Dixon technique
is described. The method differs from the three‐point Dixon method used in conventional …

Fast three-point Dixon MR imaging using low-resolution images for phase correction: a comparison with chemical shift selective fat suppression for pediatric …

FJ Rybicki, T Chung, J Reid… - American Journal of …, 2001 - Am Roentgen Ray Soc
OBJECTIVE. The purpose of this study is to describe and to implement a new fast three-point
Dixon MR imaging sequence with online image reconstruction, and to compare this …

Fat suppression in MR imaging: techniques and pitfalls

EM Delfaut, J Beltran, G Johnson, J Rousseau… - Radiographics, 1999 - pubs.rsna.org
Fat suppression is commonly used in magnetic resonance (MR) imaging to suppress the
signal from adipose tissue or detect adipose tissue. Fat suppression can be achieved with …

A three‐point Dixon method for water and fat separation using 2D and 3D gradient‐echo techniques

Y Wang, D Li, EM Haacke… - Journal of Magnetic …, 1998 - Wiley Online Library
A water and fat separation technique based on a three‐point Dixon method using two‐
dimensional (2D) and three‐dimensional (3D) gradient‐echo sequences and a new phase …

T2‐weighted spine imaging with a fast three‐point Dixon technique: comparison with chemical shift selective fat suppression

J Ma, SK Singh, AJ Kumar, NE Leeds… - Journal of Magnetic …, 2004 - Wiley Online Library
Purpose To develop a phased‐array coil‐compatible, fast three‐point Dixon (TPD)
technique, and compare its performance in T2‐weighted spine imaging with that of the …

Dixon techniques for water and fat imaging

J Ma - Journal of Magnetic Resonance Imaging: An Official …, 2008 - Wiley Online Library
In 1984, Dixon published a first paper on a simple spectroscopic imaging technique for
water and fat separation. The technique acquires two separate images with a modified spin …