25-hydroxy-Vitamin D status: limitations in comparison and clinical interpretation of serum-levels across different assay methods.

D Enko, L Fridrich, E Rezanka, R Stolba, J Ernst… - Clinical …, 2014 - europepmc.org
Background: Over the last decade, clinical interest to evaluate human 25-hydroxy-vitamin D
(25 [OH] D) serum levels has increased exponentially. In the present study, four …

Accuracy of 6 routine 25-hydroxyvitamin D assays: influence of vitamin D binding protein concentration

AC Heijboer, MA Blankenstein, IP Kema… - Clinical …, 2012 - academic.oup.com
BACKGROUND Recent recognition of its broad pathophysiological importance has
triggered an increased interest in 25-hydroxyvitamin D [25 (OH) D]. By consequence …

Accuracy and clinical implications of seven 25-hydroxyvitamin D methods compared with liquid chromatography–tandem mass spectrometry as a reference

HJ Roth, H Schmidt-Gayk, H Weber… - Annals of clinical …, 2008 - journals.sagepub.com
Background The most reliable assessment of vitamin D status is measurement of plasma 25-
hydroxyvitamin D (25 [OH] D) concentration. High variability in 25 (OH) D measurements …

Current status of clinical 25-hydroxyvitamin D measurement: an assessment of between-laboratory agreement

N Binkley, DC Krueger, S Morgan, D Wiebe - Clinica Chimica Acta, 2010 - Elsevier
BACKGROUND: Historically, methodological differences and lack of standardization led to
between-laboratory variability in 25 (OH) D results. Recent observations raised concern …

Interlaboratory comparison of 25-hydroxyvitamin D determination.

E Mayer, H Schmidt-Gayk - Clinical chemistry, 1984 - academic.oup.com
This interlaboratory study on determination of 25-hydroxyvitamin D (25-OH-D) in serum
involved 15 laboratories in eight European countries. All could distinguish between normal …

[HTML][HTML] Serum 25-hydroxyvitamin D measurement: comparative evaluation of three automated immunoassays

F Trimboli, S Rotundo, S Armili, S Mimmi… - Practical Laboratory …, 2021 - Elsevier
Objectives: the different analytical methods for measurement of serum 25-hydroxyvitamin D
(25 (OH) D) are not yet fully harmonized and no consensus exists on a threshold of 25 (OH) …

Correlation among 25-hydroxy-vitamin D assays

N Binkley, D Krueger, D Gemar… - The Journal of Clinical …, 2008 - academic.oup.com
Context: Measurement of circulating 25-hydroxy-vitamin D [25 (OH) D]) is the accepted
clinical indicator of vitamin D status. However, between-laboratory differences in …

Influence of Vitamin D2 Percentage on Accuracy of 4 Commercial Total 25-Hydroxyvitamin D Assays

I Shu, S Pina-Oviedo, G Quiroga-Garza… - Clinical …, 2013 - academic.oup.com
25-Hydroxyvitamin D (25-OHD) 1 is the most appropriate marker for monitoring vitamin D
storage status. The 2 major forms of 25-OH-D [25-OH-D2 (D2) and 25-OH-D3 (D3)], differ …

[HTML][HTML] Performance evaluation of four 25-hydroxyvitamin D assays to measure 25-hydroxyvitamin D2

J Freeman, K Wilson, R Spears, V Shalhoub… - Clinical biochemistry, 2015 - Elsevier
Objectives The ability of current immunoassays to accurately measure equimolar amounts of
25 (OH) D 2 and 25 (OH) D 3 has been recently questioned. This study determined serum …

Comparison of four current 25-hydroxyvitamin D assays

HW Moon, JH Cho, M Hur, J Song, GY Oh, CM Park… - Clinical …, 2012 - Elsevier
OBJECTIVES: The performance of recently developed vitamin D total assays (ADVIA
Centaur and Elecsys) was compared to that of liquid chromatography–tandem mass …