Study on high frequency current interruption characteristics of vacuum circuit breaker

K Kojima, R Oshiro, E Kaneko - 2016 27th International …, 2016 - ieeexplore.ieee.org
It is well known that vacuum circuit breakers (VCB) have such superior characteristics as
small size, light weight, small noise, frequent interruption, easy maintenance, and no …

Study on dielectric recovery characteristics after high frequency current interruption in vacuum circuit breaker with short gap

S Tamaki, K Ganaha, S Miyamoto… - … on Discharges and …, 2014 - ieeexplore.ieee.org
When inductive load is interrupted by VCB, extinction and re-ignition may be observed
repeatedly by balance with recovery voltage. This is due to high frequency current …

Influence of the commutation current frequency on the vacuum DC interruption

Y Zhang, T Qin, Y Dai, E Dong… - 2018 28th International …, 2018 - ieeexplore.ieee.org
Interrupting frequency has a great influence on the breaking capacity of the breakers. In this
paper, using the forced current zero method, vacuum DC interruptions were carried out in …

Simulation and experimental research on series vacuum arc of vacuum circuit breaker with double-break

M Liao, G Ge, X Duan, K Su, X Cheng… - … on Discharges and …, 2014 - ieeexplore.ieee.org
The paper established the simulation model of series vacuum arc of Vacuum Circuit Breaker
(VCB) with double-break using Magneto Hydro Dynamic (MHD) model. To gain the …

Interruption capability of a fast vacuum circuit breaker with a short arcing time

B Zhang, Y Tan, L Ren, J Wang, Y Geng… - … on Discharges and …, 2016 - ieeexplore.ieee.org
With a capacity increase of the power system, the fault current increases very quick and it
becomes a threat for other equipment in the power system. Vacuum interrupter combined …

Rebreakdown Characteristics of Vacuum Circuit Breaker in its Breaking Process under DC Voltage

J Sun, Z Li, H Wang, J Liu, D Lei… - 2023 IEEE 4th …, 2023 - ieeexplore.ieee.org
The repeated breakdown of vacuum circuit breaker during the breaking process causes
overvoltage and intensifies the insulation deterioration of high-voltage equipment. The work …

Interruption performance at frequency 50 or 60Hz for generator breaker equipped with vacuum interrupters

D Gentsch, S Goettlich, M Wember… - … on Discharges and …, 2014 - ieeexplore.ieee.org
Vacuum interrupters are serving worldwide in distribution circuits, meeting the electrical and
mechanical requirements specified in the IEC and/or ANSI standards for low and medium …

Experiment research on current chopping on zero period of DC vacuum circuit breaker breaking

X Li, J Zou, L Geng, Z Bi - 2017 4th International Conference on …, 2017 - ieeexplore.ieee.org
Dielectric recovery after arc extinguishes in vacuum circuit breaker is very fast, the arc
current may be cut off before natural current zero. In order to study the current zero period …

Experimental investigation of influence of a contact separation time on the breaking capacity of a vacuum circuit breaker

VA Lavrinovichi, SA Popov… - … on Discharges and …, 2014 - ieeexplore.ieee.org
In the present work, influence of the beginning of the contact opening of the vacuum circuit
breaker on the main characteristics of the discharge and the breaking capacity of the …

Restrike characteristics of vacuum circuit breaker in its opening process under DC voltage

J Sun, Y Fan, J Liu, J Huo, S Song… - IET Science …, 2023 - Wiley Online Library
The restrike of vacuum circuit breaker during the breaking process causes overvoltage and
intensifies the insulation deterioration of high‐voltage equipment. To solve this problem, the …