The application of synchronous grid connection in power supply system

S Xiao, K Xu - 2010 5th International Conference on Critical …, 2010 - ieeexplore.ieee.org
When large power supply system becomes isolated after fault occurred, the best method is
finding a suitable grid-connected point to connect with external power system to maintain …

The researches on adaptive synchronized grid-connected of small generator

H Tao, C Kuai, Y Zi-de, W Jia-liang… - 2011 4th International …, 2011 - ieeexplore.ieee.org
Automatic synchronized grid-connected requires that voltage difference, frequency
difference and phase angle difference between power network and generator are all in the …

Grid synchronization technology for distributed power generation system

Y Li, J Li, Y Lei, W Sun - 2014 IEEE Conference and Expo …, 2014 - ieeexplore.ieee.org
Grid synchronization is one of the key issues for distributed power generation system. In
recent years, an increasing number of new energy generation systems are connected to the …

Transient Stability Analysis for Small Electric Power Grid

T Chen, Z Xu, K Luo - 2010 International Conference on …, 2010 - ieeexplore.ieee.org
With the developing of power system, there many power plant of HUBEI JINGZHOU CHINA
with small generation capacity interconnected with weak lines and more and more small …

Analysis of the effect of distributed generation on power grid

HY Li, SY Ge, H Liu - 2012 Asia-Pacific Power and Energy …, 2012 - ieeexplore.ieee.org
Due to the characteristics of flexible, low investment, environment friendly, and many other
significant advantages, distributed power generation technologies will be used more in …

Black Start and Synchronization of Microgrid Considering Distributed Generation Control

JY Choi, DJ Won - The Transactions of the Korean Institute of …, 2013 - koreascience.kr
In order to minimize the damage from power outage, power system should be restored
quickly. In this paper, a procedure for the restoration of microgrid is proposed. After …

[PDF][PDF] Detection of Power Grid Synchronization Failure by Sensing Bad Voltage and Frequency

S Wadhai, M Wadekar, S Junankar, C Rathod… - 2017 - academia.edu
This project developed to minimize the power grid synchronization failure and the main
intention of this project is to detect the failure of power grid synchronization while sensing …

Study on grid-connection of powerformer

J Zhao, B Ge, P Lin, D Tao - 2009 Asia-Pacific Power and …, 2009 - ieeexplore.ieee.org
Grid-connection is the first link of electric energy transport, which will impact generator on
safety and electric power grid steady. Powerformer can generate high voltage of the grid …

The investigation on Chinese nationwide interconnected grid in future

J Guo, G Yao, Z Xu, Y Yin - 2000 IEEE Power Engineering …, 2000 - ieeexplore.ieee.org
This paper describes a Chinese nationwide interconnected grid. Based on the results of
power system analysis, some technical problems of the interconnected grid are discussed …

Grid connected-induction generator start-up sequence observation using laboratory simulator

FD Wijaya, E Firmansyah… - 2015 IEEE Innovative …, 2015 - ieeexplore.ieee.org
Start-up, loading, and shut-down procedure of induction generator is different from
synchronous generator. At the initial time of grid connection, induction generator's voltage is …