Advanced methods for the characterization of few-cycle light pulses: a comparison

G Stibenz, C Ropers, C Lienau, C Warmuth, AS Wyatt… - Applied Physics B, 2006 - Springer
We discuss and compare four methods for measuring the width and pulse profile of
ultrashort pulses. For our comparison, we use stable sub-7 fs pulses from a Ti: sapphire …

Spectro-temporal imaging of optical pulses with a single time lens

J Azaña, NK Berger, B Levit… - IEEE Photonics …, 2004 - ieeexplore.ieee.org
Spectro-temporal imaging (time-to-frequency conversion) constitutes a simple and direct
(single-shot) technique for the high-resolution measurement of fast optical temporal …

Generation and measurement of 200 femtosecond optical pulses

JC Diels, E Van Stryland, G Benedict - Optics Communications, 1978 - Elsevier
Pulses as short as 0.2 ps have been obtained from a passively mode locked dye laser. The
technique is simpler than those previously used, but one must pay the price of a loss of …

Amplitude and phase measurement of mid-infrared femtosecond pulses by using cross-correlation frequency-resolved optical gating

DT Reid, P Loza-Alvarez, CTA Brown, T Beddard… - Optics letters, 2000 - opg.optica.org
We describe a cross-correlation-based frequency-resolved optical gating (XFROG)
technique for simultaneously measuring the amplitude and phase of two ultrashort pulses …

Using phase retrieval to measure the intensity and phase of ultrashort pulses: frequency-resolved optical gating

R Trebino, DJ Kane - JOSA A, 1993 - opg.optica.org
We recently introduced a new technique, frequency-resolved optical gating (FROG), for
directly determining the full intensity I (t) and phase φ (t) of a single femtosecond pulse. By …

Measurement of the optical phase relation among subharmonic pulses in a femtosecond optical parametric oscillator

Y Kobayashi, K Torizuka - Optics Letters, 2000 - opg.optica.org
We observed the phase relation among subharmonic pulses generated by a femtosecond
optical parametric oscillator (OPO). The ratio of the optical frequencies of the idler, the …

Chronocyclic tomography for measuring the amplitude and phase structure of optical pulses

M Beck, MG Raymer, IA Walmsley, V Wong - Optics letters, 1993 - opg.optica.org
We describe a new method—chronocyclic tomography—for determining the amplitude and
phase structure of a short optical pulse. The technique is based on measurements of the …

[引用][C] 150 Gsample/s wavelength division sampler with time-stretched output

AS Bhushan, F Coppinger, B Jalali, S Wang… - Electronics Letters, 1998 - IET
A new technique for optical sampling and time stretching of an analogue signal is presented.
The signal is 'wavelength stamped'by a chirped optical pulse. An arrayed waveguide grating …

Shaping of picosecond pulses for pumping optical parametric amplification

JA Fülöp, ZS Major, B Horváth, F Tavella, A Baltuška… - Applied Physics B, 2007 - Springer
The use of temporally shaped pump pulses for optical parametric chirped-pulse
amplification can increase the efficiency and suppress possible spectral distortions in this …

Optical sampling oscilloscope using nonlinear fibre loop mirror

BP Nelson, NJ Doran - Electronics letters, 1991 - infona.pl
Optical sampling oscilloscope using nonlinear fibre loop mirror × Close The Infona portal uses
cookies, ie strings of text saved by a browser on the user's device. The portal can access …