Variability caused by setup and operating conditions for conducted EMI of switched mode power supplies over the 2–1000 kHz interval

A Mariscotti, L Sandrolini… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
… the switching byproducts and disturbance repetition rate [13]. … R1 is responsible for a slight
attenuation of the signal … into the acquired signal, a high-pass filter on the y1 signal line is …

Development and repetitive learning control of lower limb exoskeleton driven by electrohydraulic actuators

Y Yang, L Ma, D Huang - IEEE transactions on industrial …, 2016 - ieeexplore.ieee.org
… to convert the current signal of the sensors’ output to voltage, four analog current/voltage
output drivers (Type: XTR300) are utilized to convert the voltage signal of the DAC to current. …

Photoconductivity null apparatus for the determination of minority carrier lifetime

WF Richardson, JM Meese… - Review of Scientific …, 1978 - pubs.aip.org
… matching tne photoconductivity signal may be easily obtained using the gain switch on the
repetitive exponential signal may be extracted from noise with the highest possible signal-to-…

A discrete-time repetitive sliding mode control for voltage source inverters

L Zheng, F Jiang, J Song, Y Gao… - IEEE Journal of emerging …, 2017 - ieeexplore.ieee.org
… , especially for the periodic signal. The combination of RC and … RC, a hybrid discrete-time
repetitive SMC (DRSMC) scheme is … The switching signal is modulated according to sinusoidal …

Central signals rapidly switch tactile processing in rat barrel cortex during whisker movements

H Hentschke, F Haiss, C Schwarz - Cerebral cortex, 2006 - academic.oup.com
… was not caused by adaptation due to repetitive contacts. Second, active touch was
accompanied by a refinement of spatial representation of tactile signals. Third, transecting the ION …

Adaptive repetitive control of a PWM inverter for AC voltage regulation with low harmonic distortion

SC Yeh, YY Tzou - Proceedings of PESC'95-Power Electronics …, 1995 - ieeexplore.ieee.org
… using state feedback control, a repetitive controller with tuning parameters, and … repetitive
controller used for ac voltage regulation has been realized by using a single-chip digital signal

Measuring pd under fast slew rate, high voltage and high frequency repetitive voltage impulses

R Ghosh, P Seri, GC Montanari - 2020 IEEE 15th International …, 2020 - ieeexplore.ieee.org
… The proposed method is effective in extreme conditions where PD pulses and switching
1 shows a few plots representing a signal recorded by 2 GHz, 6.25 GSa/s oscilloscope and an …

A measurement apparatus for switching losses based on an heat-flux sensor

D Iero, FG Della Corte, G Fiorentino… - 2015 XVIII AISEM …, 2015 - ieeexplore.ieee.org
… is not suitable for very high switching frequencies and highly distorted signals. In fact, the …
The apparatus has been used to measure losses of devices operating in dynamic repetitive

A calorimetry-based measurement apparatus for switching losses in high power electronic devices

D Iero, FG Della Corte, G Fiorentino… - 2016 IEEE …, 2016 - ieeexplore.ieee.org
… in DC and with arbitrary electric signals. After performing the calibration, the heat … apparatus
has been realized and used to measure losses of devices operating in dynamic repetitive

A Fast Repetitive Control Strategy for a Power Conversion System

J Zhou, Y Sun, S Chen, T Lan - Electronics, 2024 - mdpi.com
… When α 0 is equal to 2, Q has basically no effect on the base frequency signal (50 Hz), …
values such as PCS voltage, current, and switch signals. Host computer 2 serves as the upper …