Experimental study on end-plate to SHS column connections reinforced by increasing wall thickness with one side bolts

T Tanaka, M Tabuchi, K Furumi, T Morita… - Tubular Structures …, 2022 - taylorfrancis.com
… the column walls from the tensile or compressive force of the beam flange. This paper includes
tests of one side bolts, material tests of the connection part where the column thickness is …

Shear behavior of lap connection using one-side bolts

P Wang, T Wulan, M Liu, H Qu, Y You - Engineering Structures, 2019 - Elsevier
… one-side bolt in the connection was clamped by internal threads on the wall of a bolt hole, …
36 test specimens with different thicknesses of screwed shear plate and different bolt pre-…

Numerical study on the resistance of thread-fixed one-side bolts: Tensile and bearing strength

M Latour, G Rizzano - Structures, 2021 - Elsevier
… Several cases have been considered within this work, varying the intermediate plate thickness,
activating different bearing strengths and failure modes. Among all the tests reported in […

Proposed analytical models for bolted T-stubs to square hollow section column connection using thread-fixed one-side bolts under tension

Y Liu, L Sun, Y Zhang, L Liu, M Liu, P Wang… - Journal of Building …, 2022 - Elsevier
… Because the SHSC wall thickness limits the depth of the bolt hole threads, the backing
plates are welded to SHSC inner surface to increase the local wall thickness and thread depth. …

Experimental study on cyclic behavior of thread-fixed one-side bolts bolted endplate connection to strengthened concrete filled square steel tube with fixed thread …

M Cai, P Wang, W Zhang, M Liu, G Zhai, FZ Liu… - Journal of Building …, 2022 - Elsevier
… , which was attributed to the tube wall thickness or the endplate thickness increasing. In
other words, adding tube wall thickness or endplate thickness can significantly decrease the …

Anchor Behavior of One-Side Bolt with Flip-Top Collapsible Washer

L Li, D Mu, Y Liu, Z Li, Q Yin, H Chang - Buildings, 2023 - mdpi.com
… By effectively adjusting the washer thickness, side wall height, and upper contact surface
size, shear failure of the washer can be avoided and an anchoring performance can be …

[PDF][PDF] The effects of bolt spacing on composite shear wall behavior

A Ayazi, H Ahmadi, S Shafaei - World Academy of Science …, 2012 - researchgate.net
wall which study in this paper has no gap around it and is merely attached to one side of the
… and have 5mm and 8mm thicknesses for steel and concrete walls respectively. These infill …

Behavior of thread-fixed one-side bolts bolted T-stubs with arc-shaped flange to steel tube under tension

L Liu, H Chen, L Sun, X Jin, S Li, P Wang, C Chen - Engineering Structures, 2023 - Elsevier
… the Thread-fixed One-side Bolts (TOBs) bolted T-stub with arc-… thickness of tube wall, the
outer diameter of steel tube, the … as the flange thickness, the tube wall thickness, the bolt center …

Experimental studies on thread-fixed one-side bolted endplate connection with internal strengthening structure

M Liu, B Zhang, Q Liu, Y Liu, L Tang, W Zhang… - Engineering …, 2021 - Elsevier
… However, the length of the internal threads on the hole wall was limited by the thickness of
the column wall, which might result in the premature failure of connection owing to the failure …

Seismic behavior of a novel bolt-connected horizontal joint for precast RC wall panel structures: Experimental and numerical analysis

YC Zhong, F Xiong, MM Ran, J Chen, Q Ge… - Journal of Building …, 2022 - Elsevier
… , connecting steel plate thickness and bolt number were … were installed at two sides (three
supports on each side) of the … 10 mm thickness mortar layer between the upper wall panel …