Estimation of strain elastography from ultrasound radio-frequency data by utilizing analytic gradient of the similarity metric

M Omidyeganeh, Y Xiao, MO Ahmad… - IEEE transactions on …, 2017 - ieeexplore.ieee.org
… To allow fast strain estimation, we analytically derive the derivative of the dissimilarity metric
with respect to the strain using the chain rule, and therefore, can use an efficient gradient-…

Optimized phase gradient measurements and phase-amplitude interplay in optical coherence elastography

VY Zaitsev, AL Matveyev, LA Matveev… - Journal of …, 2016 - spiedigitallibrary.org
… be rather pronounced and should be taken into account when interpreting the elastographic
strain maps obtained via phase-gradient analysis. Note that normalization of the OCT-image …

Strain elastography-how to do it?

CF Dietrich, RG Barr, A Farrokh… - Ultrasound …, 2017 - thieme-connect.com
… of RF echo frames and the strain calculated from the axial gradient of the displacements. Under
… For liver fibrosis analysis, using an intercostal space as a window, the transducer can be …

Analysis of an adaptive strain estimation technique in elastography

S Srinivasan, F Kallel, R Souchon… - Ultrasonic …, 2002 - journals.sagepub.com
Elastography is based on the estimation of strain due to tissue compression or expansion.
Conventional elastography involves computing strain as the gradient of the displacement (time…

A theoretical framework for performance characterization of elastography: The strain filter

T Varghese, J Ophir - IEEE transactions on ultrasonics …, 1997 - ieeexplore.ieee.org
… The strain filter consists of a graphical and analytical representation of the allowable range
… The slope of the strain filter for low strain values is determined primarily by electronic noise …

An automatic differentiation-based gradient method for inversion of the shear wave equation in magnetic resonance elastography: specific application in fibrous soft …

S Chatelin, I Charpentier, N Corbin… - Physics in Medicine …, 2016 - iopscience.iop.org
analysis (DMA) in a parallel-plate configuration under controlled temperature (22.5 C). Strain
sweep experiments are first performed to confirm the linear viscoelastic region (shear strain

Gradient-based optimization for poroelastic and viscoelastic MR elastography

L Tan, MDJ McGarry, EEW Van Houten… - IEEE transactions on …, 2016 - ieeexplore.ieee.org
… an infinitesimal strain tensor; λ and µ are the Lamé’s material parameters (µ is the shear
modulus), which are the material parameters θ to be reconstructed in the elastography problem. …

An adaptive strain estimator for elastography

SK Alam, J Ophir, EE Konofagou - IEEE transactions on …, 1998 - ieeexplore.ieee.org
strain due to applied tissue compression. In conventional elastography, strain is computed
from the gradientGradient-based estimation methods are known to be susceptible to noise. In …

Comparative evaluation of strain-based and model-based modulus elastography

MM Doyley, S Srinivasan, SA Pendergrass… - Ultrasound in medicine …, 2005 - Elsevier
… and, fourth, the spatial variation of the induced internal tissue strains is estimated by performing
cross-correlation analysis on the pre- and postdeformed RF echo frames. The measured …

Magnetic resonance elastography using 3D gradient echo measurements of steady‐state motion

JB Weaver, EEW Van Houten, MI Miga… - Medical …, 2001 - Wiley Online Library
… bottom figure (B) is its reconstructed elastography counterpart. The thresholds for the volume
… (B) shows the shear modulus distribution from a 2D plane-strain reconstruction in the same …