Subassemblage tests on seismic behavior of double-corrugated-plate shear walls

JZ Tong, RM Wu, ZY Xu, YL Guo - Engineering Structures, 2023 - Elsevier
… ], which was consistent with the actual work conditions and structural characteristics of the
corrugated shear wall, and the hysteresis test in this study also followed this loading principle. …

Subassembly testing and modeling of self-centering steel plate shear walls

PM Clayton, JW Berman, LN Lowes - Engineering Structures, 2013 - Elsevier
… A second phase, Phase II, of subassemblage testing was conducted to investigate
additional SC-SPSW design variations including HBE depth, web plate-to-fish plate connection …

Experimental evaluation of posttensioned hybrid coupled wall subassemblages

YC Kurama, BD Weldon, Q Shen - Journal of Structural Engineering, 2006 - ascelibrary.org
… Single strand steel wedge/barrel anchors were used to pull the PT strands until failure,
resulting in anchor conditions similar to those in the subassemblage experiments. The strand …

Nonlinear Static Analysis of Shear Wall Sub-assemblages Based on the Uniaxial Spring Model

KM Kim, SH Oh, SH Lee, HS Lee - Journal of the Earthquake …, 2012 - koreascience.kr
shear walls and rink members of slabs and lintels. In this study, the nonlinear static analysis
of two RC shear wall … of the specimen in accordance with the test result. On the other hand, …

[PDF][PDF] NUMERICAL SIMULATION OF LATERAL LOADING TESTS ON FULL SCALE MASONRY SUBASSEMBLAGES

F Parisi, GP Lignola, N Augenti, A Prota… - Proc. of the 11th North …, 2011 - academia.edu
… loading tests on a simple tuff masonry subassemblage with … two tests were carried out on
the URM subassemblage in as … the third test was carried out on the subassemblage repaired …

Seismic behavior of structural subassemblages

EP Popov - Journal of the Structural Division, 1980 - ascelibrary.org
… In experiments the behavior of a structure can be reasonably well simulated by a subassemblage.
A … shear wall in a reinforced concrete structure, experiments show that the factors µ 0 …

Nonlinear behavior of posttensioned hybrid coupled wall subassemblages

Q Shen, YC Kurama - Journal of Structural Engineering, 2002 - ascelibrary.org
subassemblages in a new type of hybrid coupled wall system for seismic regions. Coupling
of concrete walls is achieved by posttensioning steel beams to the walls … hybrid coupled wall

Seismic behavior of sheathed cold-formed structures: physical tests

R Landolfo, L Fiorino, GD Corte - Journal of Structural Engineering, 2006 - ascelibrary.org
wall subassemblages (Della Corte et al. 2003; Fiorino et al. 2004). One subassemblage was
tested under … The generic stud shear wall subassemblage is considered a good prototype of …

Experimental investigation of the sliding failure mode in full-scale squat reinforced concrete shear wall specimen

D Pizarro Pohl, M Kovarbasic… - Proceedings of the …, 2022 - research-collection.ethz.ch
… Due to their low aspect ratio, they are prone to shear or sliding failure. A shear wall was
subjected to a cyclic test at the new Multi-Axis Sub-Assemblage Testing (MAST) facility at ETH …

Ductility evaluation of precast RC shear walls in Italian existing buildings

M Breccolotti, L Brocchi, AL Materazzi - Engineering Structures, 2021 - Elsevier
… impossibility of being able to perform experimental tests on specimens of the different
precast RC wall techniques. Displacement controlled tests have been simulated using non-linear …