Tuned liquid dampers for controlling earthquake response of structures

P Banerji, M Murudi, AH Shah… - … engineering & structural …, 2000 - Wiley Online Library
… By convention, a tuned liquid damper implies that this tuning ratio is unity. Earlier experimental
studies [7,13] have, however, shown that the optimum tuning ratio may depend on many …

Performance of tuned liquid dampers

MJ Tait, N Isyumov, AA El Damatty - Journal of Engineering …, 2008 - ascelibrary.org
tuned liquid dampers (TLDs) under random excitation. The performance of the tuned liquid
dampers … on model scale structure-tuned liquid damper systems to evaluate their performance…

Effectiveness of tuned liquid dampers under wind excitation

Y Tamura, K Fujii, T Ohtsuki, T Wakahara… - Engineering …, 1995 - Elsevier
tuned liquid dampers (TLDs). The damping ratios of the buildings with and without TLD were
evaluated by both the run-down test technique and the random decrement technique. The …

Optimization of tuned liquid column dampers

H Gao, KCS Kwok, B Samali - Engineering structures, 1997 - Elsevier
tuned liquid column damper. The results of this study reveal that a V-shaped tuned liquid
column damper … vibrations than the corresponding Ushaped damper with a similar efficiency. …

Vibration control by multiple tuned liquid dampers (MTLDs)

Y Fujino, LM Sun - Journal of Structural Engineering, 1993 - ascelibrary.org
tuned liquid damper (TLD) is a passive control device that consists of rigid tank(s) filled with
liquid … Semi-analytical modelling of tuned liquid damper (TLD) with emphasis on damping of …

A review on various configurations of the passive tuned liquid damper

T Konar, A Ghosh - Journal of Vibration and Control, 2023 - journals.sagepub.com
… which a systematic review on tuned liquid dampers of various configurations for … the dampers.
To organize the review in a structured manner, the large family of tuned liquid dampers is …

Investigation of tuned liquid dampers under large amplitude excitation

D Reed, J Yu, H Yeh, S Gardarsson - Journal of engineering …, 1998 - ascelibrary.org
The behavior of tuned liquid dampers (TLD) was … It was found that the response frequency of
tuned liquid dampers … system, the design frequency for the damper, if it is computed by the …

Optimum absorber parameters for tuned liquid column dampers

SK Yalla, A Kareem - Journal of Structural Engineering, 2000 - ascelibrary.org
… ABSTRACT: Tuned liquid column dampers (TLCDs) are a class of tuned liquid dampers that
impart indirect damping to the primary structure through oscillations of the liquid column in a …

Single‐and multiple‐tuned liquid column dampers for seismic applications

F Sadek, B Mohraz, HS Lew - Earthquake engineering & …, 1998 - Wiley Online Library
… Design examples using single- and multiple-tuned liquid column dampers in a bridge and a
… with tuned liquid column dampers is compared with that using tuned mass dampers where it …

Tuned liquid damper (TLD) for suppressing horizontal motion of structures

Y Fujino, L Sun, BM Pacheco… - Journal of engineering …, 1992 - ascelibrary.org
… The installation of various types of passive devices including mechanical dampers, is one
… mechanical damper, tuned liquid damper (TLD), which relies on the motion of shallow liquid