Validation protocols for blood pressure measuring devices in the 21st century

GS Stergiou, BS Alpert, S Mieke… - The Journal of …, 2018 - Wiley Online Library
… for clinical validation of an automated BP monitor.3 The British Hypertension Society
presented a similar clinical validation protocol in 1990.4 Revised versions of both protocols have …

Accuracy of ambulatory blood pressure monitors: a systematic review of validation studies

JA Hodgkinson, JP Sheppard, C Heneghan… - Journal of …, 2013 - journals.lww.com
… to the underlying protocols, undermining … validation showed significant variation in blood
pressure from the reference standard, highlighting inadequacies in older validation protocols

Validation protocols for blood pressure-measuring devices: status quo and development needs

B Beime, C Deutsch, T Gomez, T Zwingers… - Blood Pressure …, 2016 - journals.lww.com
… , blood pressure ranges, and the length of the validation procedure, … to ensure the efficacy
of blood pressure-measuring devices … four currently used validation protocols and to initiate a …

European Society of Hypertension International Protocol for the validation of blood pressure monitors: a critical review of its application and rationale for revision

GS Stergiou, N Karpettas, N Atkins… - Blood Pressure …, 2010 - journals.lww.com
… To perform a systematic review of validation studies of blood pressure measuring devices
done using the European Society of Hypertension International Protocol (ESH-IP) since its …

Validation protocols for blood pressure measuring devices: the impact of the European Society of Hypertension International Protocol and the development of a …

, … Working Group on Blood Pressure … - Blood pressure …, 2019 - journals.lww.com
… In the last three decades protocols for the validation of blood pressure measuring devices
have been developed by the US Association for the Advancement of Medical Instrumentation, …

A novel and simple protocol for the validation of home blood pressure monitors in clinical practice

K Eguchi, S Kuruvilla, J Ishikawa… - Blood Pressure …, 2012 - journals.lww.com
… We sought to devise a method for validating individual home blood pressure (HBP) … We
used only systolic blood pressure to simplify the protocol. In step 1, the number of monitors in …

Clinical validation protocols for noninvasive blood pressure monitors and their recognition by regulatory authorities and professional organizations: rationale and …

KG Ng - Blood Pressure Monitoring, 2013 - journals.lww.com
… Review of measurement methods and clinical validation studies of noninvasive blood
pressure monitors: accuracy requirements and protocol considerations for devices that require …

Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in …

E O'Brien, T Pickering, R Asmar, M Myers… - Blood pressure …, 2002 - journals.lww.com
pressure measurement, many of whom have considerable experience in validating blood
pressure … The AAMI published its first protocol for the validation of blood pressure measuring …

Validation of four automatic devices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension

J Belghazi, RN El Feghali, T Moussalem… - Vascular health and …, 2007 - Taylor & Francis
Full article: Validation of four automatic devices for self-measurement of blood pressure
according to the International Protocol of the European Society of Hypertension Skip to Main …

Validation of non-invasive central blood pressure devices: ARTERY Society task force consensus statement on protocol standardization

JE Sharman, AP Avolio, J Baulmann… - European heart …, 2017 - academic.oup.com
… Peripheral (non-invasive) blood pressure Blood pressure at a site distal from the aorta. This
… artery blood pressure, but for the purpose of this paper also includes carotid blood pressure