Risk assessment of circuit breakers using influence diagrams with interval probabilities

JD Velimirovic, A Janjic - Symmetry, 2021 - mdpi.com
… the operation of a circuit breaker, as well as indicators of its condition, … Replacing the most
risky circuit breakers is a good basis for … the mechanism, as well as frequent visual inspection. …

Radiometric monitoring technique for high-voltage circuit breakers

AC de Oliveira, EG da Costa… - … on Power Delivery, 2019 - ieeexplore.ieee.org
In this study, a new technique for circuit breaker diagnosis, based on broadband microstrip
antennas, is presented. The diagnosis is based on the electromagnetic signals radiated by …

Automated monitoring and analysis of circuit breaker operation

M Kezunovic, Z Ren, G Latisko… - … on Power Delivery, 2005 - ieeexplore.ieee.org
… signals from the control circuitry is taken. The maintenance crew visually analyzes the record
… changes, CB mechanism actions and related waveform indications. Signals collected from …

Providing decision support for the condition-based maintenance of circuit breakers through data mining of trip coil current signatures

SM Strachan, SDJ McArthur, B Stephen… - … on Power Delivery, 2006 - ieeexplore.ieee.org
… into a more visually appreciable two-dimensional (2-D) representation [11]. The Sammon
map distribution of the plotted feature vectors offers a visual indication of the number of clusters …

Experiences with condition monitoring of HV circuit breakers

A Poeltl, M Haines - 2001 IEEE/PES Transmission and …, 2001 - ieeexplore.ieee.org
… to the CMU breaker monitoring package by including it on all future 500kV circuit breaker
orders. As a … They would see a yellow or red light for visual indication that they have in fact …

Artificial intelligence SF6 circuit breaker health assessment

M Žarković, Z Stojković - Electric power systems research, 2019 - Elsevier
… of high voltage SF6 circuit breakers. Paper presents an … indicators of the state of high
voltage SF6 circuit breakers. Special attention is devoted to identifying and determining indicator

Condition monitoring of high voltage circuit breakers

MHB De Grijp, JS Bedet, RA Hopkins… - Proceedings of IEEE …, 1996 - ieeexplore.ieee.org
… If a clear trend is visible, the necessary actions can be taken such as a visual check or …
operating time gives an indication of a change in the condition of the circuit breaker main contacts. …

Embedded system and software application for monitoring and diagnosis of high voltage circuit breakers

M Andruşcă, M Adam, FD Irimia… - … and Exposition on …, 2012 - ieeexplore.ieee.org
Circuit breakers have a very important role in generation and transmission of electricity and
represent a vital part of the power system. Monitoring the high voltage circuit breakers

In-service early indication of 500 kV circuit breaker function loss operated in PLN P3B Jawa Bali-Indonesia

Y Wibisana, RS Wibowo… - Proceedings of the 2011 …, 2011 - ieeexplore.ieee.org
… By using this inservice early indication of function loss, we will able to obtain symptoms to …
Early Indication of Function Loss in circuit breaker that we called inspection level 1 (visual

Performance evaluation based on symptom, failed-type and obsolescence criteria of high voltage circuit breaker

T Suwanasri, C Suwanasri, S Nobnorp… - 2013 10th …, 2013 - ieeexplore.ieee.org
… For symptom criterion, weighting factors of 11 symptom aspects for HV circuit breaker such
as the visual inspection, diagnostic tests, failure frequency, deterioration of steel structure and …