Experimental flowloop investigations of gas hydrate formation in high water cut systems

SV Joshi, GA Grasso, PG Lafond, I Rao, E Webb… - Chemical Engineering …, 2013 - Elsevier
… the fluids through the loop, which can operate at RPMs from 300 to 1500. The pump RPM
is calibrated with measured flowrate for single-phase flow (water). For two-phase gas–liquid …

Dynamic characterization of a low cost microwave water-cut sensor in a flow loop

MA Karimi, M Arsalan, A Shamim - Sensors and Actuators A: Physical, 2017 - Elsevier
… This work focuses on dynamic flow loop characterization of a novel microwave WC … (oil,
water) flow loop which was used to characterize the novel microwave resonator based water-cut

Investigation of hydrate plugging in natural gas+ diesel oil+ water systems using a high-pressure flow loop

GC Song, YX Li, WC Wang, K Jiang, X Ye… - Chemical Engineering …, 2017 - Elsevier
… mechanisms, a high-pressure flow loop was newly designed and constructed where …
gas+diesel oil+water systems for a range of water cuts (30–100%) and initial liquid flow rates (1600–…

Flow patterns and water wetting in oil-water two phase flow–a flow loop study

KE Kee, S Richter, M Babic, S Nesic - NACE CORROSION, 2014 - onepetro.org
… of water under different oil-water flow conditions … water or oil phase. In this experimental
work, a large scale 0.1m ID inclinable flow loop was used to study the two phase oil-water flow in …

Flow patterns and water wetting in gas-oil-water three-phase flow–A flow loop study

KE Kee, M Babic, S Richter, L Paolinelli, W Li… - NACE …, 2015 - onepetro.org
… 0.1 m ID inclinable flow loop was used to study the three-phase gas-oil-water flow in horizontal
and … for flow pattern visualization and surface wetting measurements, respectively. The …

Experimental study of oil-water flow patterns in a large diameter flow loop—the effect on water wetting and corrosion

KE Kee, S Richter, M Babic, S Nešić - Corrosion, 2016 - meridian.allenpress.com
… distribution of water under different oil-water flow conditions … the wall surface is wetted by
water or oil phase. In this … inclinable flow loop was used to study the two phase oil-water flow in …

Single and multi-phase flow loop testing results for industry standard inflow control devices

JE Lauritzen, IB Martiniussen - SPE Offshore Europe Conference and …, 2011 - onepetro.org
flow performance at the Statoil multi-phase flow loop facility in Porsgrunn, Norway. The test
results are given as performance curves for single phase oil, water … gas and water cut multi-…

An accurate machine for real-time two-phase flowmetering in a laboratory-scale flow loop

M Meribout, NZ Al-Rawahi… - IEEE Transactions …, 2009 - ieeexplore.ieee.org
… laboratory-scale two-phase flow loop under various flow regimes, water cuts, and flow rate
ranges. Fig. 11 shows a block diagram of the two-phase flow loop in which the experiments …

Wax deposition of water-in-crude oil emulsion in a flow-loop apparatus

Q Quan, W Wang, P Wang, Y Zhou… - Petroleum Science and …, 2015 - Taylor & Francis
… deposition of water-in-oil dispersed flow with different water cuts in the flow-loop and high
… The viscosity and gelation point of emulsions increase with water cut. The role of gelation in …

Experimental study of single-phase and two-phase water-in-crude-oil dispersed flow wax deposition in a mini pilot-scale flow loop

E Panacharoensawad, C Sarica - Energy & fuels, 2013 - ACS Publications
… possible effects of water cut on F̅ w as water cut increases (staying the same, increasing,
and decreasing), and Bruno (6) and Couto (4) found different effects of water cut on F̅ w . …