A fully integrated 8-channel closed-loop neural-prosthetic CMOS SoC for real-time epileptic seizure control

WM Chen, H Chiueh, TJ Chen, CL Ho… - IEEE journal of solid …, 2013 - ieeexplore.ieee.org
… To address these issues, we develop a fully integrated SoC composed … closed-loop epileptic
seizure control [10]. High detection accuracy % within 0.8 s has been achieved for real-time

… integrated 16-channel closed-loop neural-prosthetic CMOS SoC with wireless power and bidirectional data telemetry for real-time efficient human epileptic seizure …

CH Cheng, PY Tsai, TY Yang… - IEEE Journal of Solid …, 2018 - ieeexplore.ieee.org
… The proposed closed-loop seizure control SoC achieves a high seizure detection … fully
integrated 8-channel closed-loop neuralprosthetic CMOS SoC for real-time epileptic seizure

[PDF][PDF] A Fully Integrated 8-Channel Closed-Loop Neural-Prosthetic CMOS SoC for Real-Time Epileptic Seizure Control

CY Wu, H Chiueh, TJ Chen, CL Ho, C Jeng, MD Ker… - scholar.archive.org
8-channel closed-loop neural-prosthetic SoC is presented for real-time intracranial EEG (iEEG)
acquisition, epileptic … To address these issues, we have developed a fullyintegrated SoC

NeuralTree: A 256-channel 0.227-μJ/class versatile neural activity classification and closed-loop neuromodulation SoC

U Shin, C Ding, B Zhu, Y Vyza… - IEEE Journal of Solid …, 2022 - ieeexplore.ieee.org
… The proposed SoC was fabricated in 65-nm CMOS 21 and … The 8-channel 562 seizure
detection SoC with 1024 … , the real-time seizure detection 784 capability of the SoC will …

Closed-loop neural prostheses with on-chip intelligence: A review and a low-latency machine learning model for brain state detection

B Zhu, U Shin, M Shoaran - IEEE transactions on biomedical …, 2021 - ieeexplore.ieee.org
… An 8-channel closed-loop iEEG-based seizure control SoC was presented in [17], … fully
integrated 8-channel closed-loop neuralprosthetic CMOS SoC for real-time epileptic seizure

Closed-Loop Implantable Neurostimulators for Individualized Treatment of Intractable Epilepsy: A Review of Recent Developments, Ongoing Challenges, and Future …

H Kassiri, A Muneeb, R Salahi… - IEEE Transactions on …, 2024 - ieeexplore.ieee.org
… By nature, closed-loop devices require processing recorded signals for real-time seizure
detection and response. Fig. 7 depicts various options for signal processing, including …

A Lossless Neural Recording SoC for Epilepsy Monitoring with up to 84.9-dB Dynamic Range and Rail-to-Rail Stimulation Artifact Tolerance

Y Liu, Y Ding, X Liu - 2024 IEEE International Symposium on …, 2024 - ieeexplore.ieee.org
real-time closed-loop neuroprosthetic systems. In this paper, we propose a novel epilepsy
management system-on-a-chip (SoC… Fab’s 0.18-μm CMOS technology. The supply voltages of …

Closed-Loop Neuromodulation System-on-Chip (SoC) for Detection and Treatment of Epilepsy

MD Ker, CH Cheng - Handbook of Biochips: Integrated Circuits and …, 2022 - Springer
… In Gigante and Goodman (2011), the closed-loop neural prosthetic system with seizure
fully integrated 8-channel closed-loop neural-prosthetic CMOS SoC for realtime epileptic seizure

A programmable EEG monitoring SoC with optical and electrical stimulation for epilepsy control

SY Lee, C Tsou, ZX Liao, PH Cheng, PW Huang… - IEEE …, 2020 - ieeexplore.ieee.org
fully integrated 8-channel closed-loop neural-prosthetic CMOS SoC for real-time epileptic
seizure … and bidirectional data telemetry for real-time efficient human epileptic seizure control,’’ …

Closed-loop neurostimulators: A survey and a seizure-predicting design example for intractable epilepsy treatment

H Kassiri, S Tonekaboni, MT Salam… - IEEE transactions on …, 2017 - ieeexplore.ieee.org
… [71] WM Chen et al., “A fully integrated 8-channel closed-loop neuralprosthetic CMOS
SoC for real-time epileptic seizure control,” IEEE J. Solid-State Circuits, vol. 49, no. …