A reform in the helium purification system of the HTR-10: γ dose rate measurement and suggestions for decommissioning

F Xie, H Li, J Cao, S Yu… - International …, 2013 - asmedigitalcollection.asme.org
A reform will be implemented in the helium purification system of the 10MW High
Temperature Gas-cooled Test Reactor (HTR-10) in China. The measurement of the γ dose
rates of facilities, including valves, pipes, dust filter, etc., in the purification system of the HTR-
10, has been performed. The results indicated that most radiation nuclides are concentrated
in the dust filter and facilities at the entrance of the helium purification system upstream of
the dust filter. Other facilities have the same γ dose rate level as the background. Based on …