[HTML][HTML] Accuracy of robot-assisted versus conventional freehand pedicle screw placement in spine surgery: a systematic review and meta-analysis of randomized …

YN Peng, LC Tsai, HC Hsu, CH Kao - Annals of translational …, 2020 - ncbi.nlm.nih.gov
YN Peng, LC Tsai, HC Hsu, CH Kao
Annals of translational medicine, 2020ncbi.nlm.nih.gov
This systematic review and meta-analysis investigated differences in accuracy, operation
time, and radiation exposure time between robot-assisted and freehand techniques for
pedicle screw insertion. Two investigators independently searched for articles on
randomized controlled trials (RCTs) published from 2012 to 2019. The final meta-analysis
included seven RCTs. We compared the accuracy of pedicle screw placement, operation
time, and radiation exposure time between robot-assisted and conventional freehand …
Abstract
This systematic review and meta-analysis investigated differences in accuracy, operation time, and radiation exposure time between robot-assisted and freehand techniques for pedicle screw insertion. Two investigators independently searched for articles on randomized controlled trials (RCTs) published from 2012 to 2019. The final meta-analysis included seven RCTs. We compared the accuracy of pedicle screw placement, operation time, and radiation exposure time between robot-assisted and conventional freehand groups. Seven RCTs included 540 patients and placement of 2,476 pedicle screws, of which 1,220 were inserted using the robot-assisted technique and 1,256 were inserted using the conventional freehand technique. The pedicle screw positions were classified using the Gertzbein and Robbins classification (grade AE). The combined results of Grade A [odds ratio (OR)= 1.68; 95% confidence intervals (CI): 0.82–3.44; P= 0.16), Grade A+ B (OR= 1.70; 95% CI: 0.47–6.13; P= 0.42), and Grade C+ D+ E (OR= 0.59; 95% CI: 0.16–2.12; P= 0.42) for the accuracy rate revealed no significant difference between the two groups. Subgroup analysis results revealed that the TiRobot-assisted technique presented a significantly improved pedicle screw insertion accuracy rate compared with that of the conventional freehand technique, based on Grade A, Grade A+ B, and Grade C+ D+ E classifications. The SpineAssist-assisted technique presented an inferior pedicle screw insertion accuracy rate compared with that of the conventional freehand technique, based on Grade A, Grade A+ B, and Grade C+ D+ E classifications. No difference between the Renaissance-assisted and conventional freehand techniques was noted for pedicle screw insertion accuracy rates, based on both Grade A (OR= 1.58; 95% CI: 0.85–2.96; P= 0.15), Grade A+ B (OR= 2.20; 95% CI: 0.39–12.43; P= 0.37), and Grade C+ D+ E (OR= 0.45; 95% CI: 0.08–2.56; P= 0.37) classifications. Regarding operation time, robot-assisted surgery had significantly longer operation time than conventional freehand surgery. The robot-assisted group had significantly shorter radiation exposure time. Regarding the pedicle screw insertion accuracy rate, the TiRobot-assisted technique was superior, the SpineAssist-assisted technique was inferior, and Renaissance was similar to the conventional freehand technique.
ncbi.nlm.nih.gov
以上显示的是最相近的搜索结果。 查看全部搜索结果