Association between contrast sensitivity function and structural damage in primary open-angle glaucoma

R Pang, J Peng, K Cao, Y Sun, XT Pei… - British Journal of …, 2024 - bjo.bmj.com
R Pang, J Peng, K Cao, Y Sun, XT Pei, D Yang, ZL Lu, N Wang
British Journal of Ophthalmology, 2024bjo.bmj.com
Aims To evaluate the association between contrast sensitivity function (CSF) and
glaucomatous structural damage in primary open-angle glaucoma (POAG). Methods A cross-
sectional study was performed with 103 patients (103 eyes) aged 25–50 years who had
POAG without any other ocular disease. CSF measurements were obtained by the quick
CSF method, a novel active learning algorithm that covers 19 spatial frequencies and 128
contrast levels. The peripapillary retinal nerve fibre layer (pRNFL), macular ganglion cell …
Aims
To evaluate the association between contrast sensitivity function (CSF) and glaucomatous structural damage in primary open-angle glaucoma (POAG).
Methods
A cross-sectional study was performed with 103 patients (103 eyes) aged 25–50 years who had POAG without any other ocular disease. CSF measurements were obtained by the quick CSF method, a novel active learning algorithm that covers 19 spatial frequencies and 128 contrast levels. The peripapillary retinal nerve fibre layer (pRNFL), macular ganglion cell complex (mGCC), radial peripapillary capillary (RPC) and macular vasculature were measured by optical coherence tomography and angiography. Correlation and regression analyses were used to assess the association of area under log CSF (AULCSF), CSF acuity and contrast sensitivities at multiple spatial frequencies with structural parameters.
Results
AULCSF and CSF acuity were positively associated with pRNFL thickness, RPC density, mGCC thickness and superficial macular vessel density (p<0.05). Those parameters were also significantly associated with contrast sensitivity at 1, 1.5, 3, 6, 12, 18 cycles per degree spatial frequencies (p<0.05) and, the lower the spatial frequency, the higher the correlation coefficient. RPC density (p=0.035, p=0.023) and mGCC thickness (p=0.002, p=0.011) had significant predictive value for contrast sensitivity at 1 and 1.5 cycles per degree, with adjusted R 2 of 0.346 and 0.343, respectively.
Conclusions
Full spatial frequency contrast sensitivity impairment, most notably at low spatial frequencies, is a characteristic change in POAG. Contrast sensitivity is a potential functional endpoint for the measurement of glaucoma severity.
bjo.bmj.com
以上显示的是最相近的搜索结果。 查看全部搜索结果