[HTML][HTML] Cracking in the concrete foundation for hydropower generators: Analyses of non-linear drying diffusion, thermal effects and mechanical loads

R Malm, M Hassanzadeh, T Gasch, D Eriksson… - 2013 - diva-portal.org
R Malm, M Hassanzadeh, T Gasch, D Eriksson, E Nordström
2013diva-portal.org
An extensive program for improvement of the hydropower plants in Sweden is currently on-
going. The aims are to secure future production and to maintain and further develop an
already high dam safety.During inspection, cracks were discovered in the concrete
foundation, near the stator and rotor spider supports, at some hydropower stations in
Sweden. The cracks were believed to be related to the function of the stator supports and to
new patterns of generator operation. In earlier times, the generators ran continuously, while …
An extensive program for improvement of the hydropower plants in Sweden is currently on-going. The aims are to secure future production and to maintain and further develop an already high dam safety.
During inspection, cracks were discovered in the concrete foundation, near the stator and rotor spider supports, at some hydropower stations in Sweden. The cracks were believed to be related to the function of the stator supports and to new patterns of generator operation. In earlier times, the generators ran continuously, while nowadays there are many stops and starts, sometimes even several times during one day. The objective of this study is to understand the complex interaction between the power generating system (stator, rotor, turbine, etc.) and the supporting concrete structure. It is important from a dam safety perspective to determine the causes of the structural cracks that have been found in-situ.
diva-portal.org