designed in MATLAB (Simulink). Here, the duty-cycle of the boost-converter is varied from
45% to 50% for an input voltage of 1 v, where a maximum output voltage was observed at
95% duty-cycle. Then the classical capacitor in the Proposed boost converter is replaced
with its fractional-order counterpart. Now, the simulated analysis of fractional-order boost
converter is carried-out for fractional-order (α) from 0.2 to 1.0 using the RC-Symmetric …