Dispersion effects in partial coherence interferometry: implications for intraocular ranging

CK Hitzenberger, A Baumgartner… - Journal of …, 1999 - spiedigitallibrary.org
… this paper to evaluate these dispersion effects for the case of intraocular ranging. Based on
… on the dispersion data of the ocular media,17–19 we calculate the dispersion induced signal …

Numerical dispersion compensation for partial coherence interferometry and optical coherence tomography

AF Fercher, CK Hitzenberger, M Sticker, R Zawadzki… - Optics express, 2001 - opg.optica.org
dispersion compensation technique for Partial Coherence Interferometry (PCI) and Optical
Coherence … In PCI ranging and OCT imaging the optical distances are determined by the …

[引用][C] Guest Editorial: Special Section on Coherence Domain Optical Methods in Biomedical Science and Clinics

VV Tuchin, H Podbielska… - Journal of Biomedical …, 1999 - spiedigitallibrary.org
… Fourteen papers on Interferometry in Biomedicine written by recognized experts in the field
… , ‘‘Dispersion effects in partial coherence interferometry: implications for intraocular ranging,’…

Refractometric low coherence interferometry: dispersion interferometry

M Bagherzadeh, AF Fercher, M Pircher… - Optical Coherence …, 2005 - spiedigitallibrary.org
… physical implicationsintraocular ranging for each ocular segment an optimum source
bandwidth exists for optimum resolution; to improve resolution beyond this point, group dispersion

Resolution-improved dual-beam and standard optical coherence tomography: a comparison

A Baumgartner, CK Hitzenberger, E Ergun… - Graefe's archive for …, 2000 - Springer
… compensation of the dispersive effects of the ocular media. This … so far been used only for
ranging and imaging within tissues … effects in partial coherence interferometry: implications for …

Early development of optical low-coherence reflectometry and some recent biomedical applications

BR Masters - Journal of Biomedical Optics, 1999 - spiedigitallibrary.org
… low-coherence light sources are used for optical ranging and … sates for the dispersive
effects of the ocular media. These … of low coherence interferometry with a dispersive delay line …

A new dispersion compensation technique for Partial Coherence Interferometry (PCI) and Optical Coherence Tomography (OCT)

AF Fercher, CK Hitzenberger, M Sticker… - … on Biomedical Optics, 2001 - opg.optica.org
Dispersion balancing is successful in standard PCI ranging and OCT imaging. However, in
ultrahigh-resolution PCI ranging … : implications for intraocular ranging,” J. Biomed. Opt., 4, 144-…

Optimal wavelength for ultrahigh-resolution optical coherence tomography

Y Wang, JS Nelson, Z Chen, BJ Reiser, RS Chuck… - Optics …, 2003 - opg.optica.org
Coherence-domain ranging in OCT is performed using a Michelson interferometer. …
For ultrahigh resolution OCT, any unbalanced dispersion in the interferometer may degrade …

The effect of water dispersion and absorption on axial resolution in ultrahigh-resolution optical coherence tomography

TR Hillman, DD Sampson - Optics express, 2005 - opg.optica.org
… or greater-order dispersion), the interferometric signal retains a … analysis (over an appropriate
wavelength range). Note that the … demonstrated the significance of sample dispersion and …

Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation

M Wojtkowski, VJ Srinivasan, TH Ko, JG Fujimoto… - Optics express, 2004 - opg.optica.org
… Therefore, variation of dispersion over the axial image range is … dispersion, where the
reference arm of the interferometer did not contain a water cell to compensate ocular dispersion. …