[PDF][PDF] Assembly of edgeless four side tileable ROICs for a wafer scale, deadzone-less camera

F Fahim - IEEE Trans. Nucl. Sci - lss.fnal.gov
edgeless with no peripheral functionality, allowing the creation of large area camera systems
… a minor fanout of a slightly larger sensor pixel to create systems with no dead zones. Table …

Large area pixel detector WIDEPIX with full area sensitivity composed of 100 Timepix assemblies with edgeless sensors

J Jakubek, M Jakubek, M Platkevic… - Journal of …, 2014 - iopscience.iop.org
… The larger detector consists of 100 Timepix devices with 300 µm thick edgeless silicon …
In close future we will test the developed large area detectors for other imaging techniques …

An analysis of the accuracy of the CyberKnife: a robotic frameless stereotactic radiosurgical system

SD Chang, W Main, DP Martin, IC Gibbs… - Neurosurgery, 2003 - journals.lww.com
… Treatment delivery precision is associated primarily with the robot and imaging system. We
… seen to account in large part for the accuracy of the system. A frameless system may initially …

Motion monitoring for cranial frameless stereotactic radiosurgery using video‐based three‐dimensional optical surface imaging

G Li, Å Ballangrud, LC Kuo, H Kang, A Kirov… - Medical …, 2011 - Wiley Online Library
… Note: the motion-magnitude scale for fSRS patient #1 (c) is larger than the rest of the
frameless treatments. The translational and rotational displacements (motion magnitudes) are …

3D surface imaging for monitoring intrafraction motion in frameless stereotactic body radiotherapy of lung cancer

T Alderliesten, JJ Sonke, A Betgen… - Radiotherapy and …, 2012 - Elsevier
… with most number of vertices (ie the surface with the largest surface area) was selected.
Next, the meshes of all other surfaces were remodeled with the mesh topology of the selected …

Clinical experience with two frameless stereotactic radiosurgery (fSRS) systems using optical surface imaging for motion monitoring

G Li, A Ballangrud, M Chan, R Ma… - Journal of applied …, 2015 - Wiley Online Library
… with 1) in-room operation at patient setup, and 2) unlimited imaging throughout treatment.
In … AlignRT cameras view tangential facial surface, thereby causing a large uncertainty in …

A frameless, armless navigational system for computer-assisted neurosurgery

A Kato, T Yoshimine, T Hayakawa, Y Tomita… - Journal of …, 1991 - thejns.org
… this frameless, armless navigational system, CT or MR-imaging … 2"3~~ With these systems,
however, the route of the surgical … the operation room is not easy because of their large scale. …

Frameless stereotactic ultrasonography: method and applications

JW Trobaugh, WD Richard, KR Smith… - … Medical Imaging and …, 1994 - Elsevier
… Additionally, a large space exists at the bottom of the ultrasound image where no echoes
were received. The corresponding MR image shows a section of uniformly dense tissue at this …

Frameless, real-time, surface imaging-guided radiosurgery: clinical outcomes for brain metastases

H Pan, LI Cerviño, T Pawlicki, SB Jiang, J Alksne… - …, 2012 - journals.lww.com
… , which facilitate the delivery of large doses of radiation, with a sharp dose falloff outside
the target volume. Although all frameless radiosurgery systems need to minimize patient …

Vertically Integrated Edgeless Photon Imaging Camera

F Fahim, G Deptuch, A Shenai, P Maj, P Kmon… - 2017 - osti.gov
… to a large area silicon sensor on … large area pixelated sensor on one end and a readout
board on the other end. The aim of the development is to create a large area, gapless camera