[HTML][HTML] Effect of prepreg storage humidity on the mixed-mode fracture toughness of a co-cured composite joint

J Mohan, A Ivanković, N Murphy - Composites Part A: Applied Science and …, 2013 - Elsevier
Composites Part A: Applied Science and Manufacturing, 2013Elsevier
The present work investigated the effect of the level of prepreg moisture content on the
mixed-mode fracture toughness of a co-cured composite joint. It was found that moisture was
stored in the prepreg as either free or bound water. It was also shown that the prepreg stores
moisture from high humidity environments as free water, while the level of bound water
remains unaffected. The excessive moisture was shown to plasticise the adhesive, lowering
the glass transition temperature. The fracture toughness decreased under mode I and mode …
The present work investigated the effect of the level of prepreg moisture content on the mixed-mode fracture toughness of a co-cured composite joint. It was found that moisture was stored in the prepreg as either free or bound water. It was also shown that the prepreg stores moisture from high humidity environments as free water, while the level of bound water remains unaffected. The excessive moisture was shown to plasticise the adhesive, lowering the glass transition temperature. The fracture toughness decreased under mode I and mode II loading as the humidity level was increased. There was a significant increase in mixed-mode toughness under low humidity conditions. Although the mixed-mode toughness reduced with increasing levels of humidity, the values never fell below that of the joints fabricated using the as-received materials.