an electrically conducting perovskite phase, has been fabricated for incorporation in
between the cell interconnect and the cathode to capture gaseous chromium species. Getter
layer has been electrochemically tested in half-cell configuration in the presence of
chromium vapor (Cr 2 O 3/Air-3% H 2 O) at 850 C for 100 hours. The electrochemical
performance remains stable as evidenced by stable current density (It) at 0.5 V applied bias …