analyzed using a two-component (TC) model. The results show that unlike the single-
component model, the TC model leads to more accurate predictions of the system's heat
transfer performance as a result of the direct influence of the NPs' distribution on the
hydrodynamics. It is found that the average Nusselt number varies non-monotonically with
the block's heights, and the trend is explained by the interplay between heat transfer …