[图书][B] Laser measurement technology: fundamentals and applications

A Donges, R Noll - 2014 - books.google.com
… Beam powers and pulse energies deployed in most of the laser measuring methods are
so small that we can limit the following considerations to the risks for the eyes. …

Wireless laser power transmission: A review of recent progress

K Jin, W Zhou - IEEE Transactions on Power Electronics, 2018 - ieeexplore.ieee.org
… of laser power transmission channel, the efficiencies of laser … system from the perspective
of power conversion. Thus, a … use of laser and PV array in the system, the methods that can …

[PDF][PDF] Performance capabilities of laser scanners–an overview and measurement principle analysis

KH Thiel, A Wehr - … Archives of Photogrammetry, Remote Sensing and …, 2004 - isprs.org
… In this chapter the performance of the introduced ranging methods are going to be … high
measurement rates of eg more than 600 k pixel/sec. Due to the limited available laser power, …

[图书][B] Effects of high-power laser radiation

J Ready - 2012 - books.google.com
… This chapter will describe methods of measuring power and energy in laser beams and
will discuss detectors that are commonly employed. It is not the intention to give a complete …

A comparative analysis of five methods of determining corneal refractive power in eyes that have undergone myopic laser in situ keratomileusis

AM Hamed, L Wang, M Misra, DD Koch - Ophthalmology, 2002 - Elsevier
method as the standard, we found that the most accurate method for determining corneal
refractive power in post-LASIK eyes was to adjust the postoperative corneal measurement

Comparison of specific energy between drilling with high power lasers and other drilling methods

RM Graves, A Araya, BC Gahan… - SPE Annual Technical …, 2002 - onepetro.org
… CO 2 lasers can operate at powers up to 1000 kW with a wavelength of 10.6 mm. The three
CO 2 lasers used in this research are located at Wright-Patterson Air Force Base in Ohio, at …

High-resolution laser-pulse method for measuring charge distributions in dielectrics

GM Sessler, JE West, G Gerhard - Physical Review Letters, 1982 - APS
… as high as 100 mJ, corresponding to a peak power of 1.GW. For most of the measurements,
… In the present paper, the laser pressure pulse impinges directly on the sample under in…

Definition and measurements of high-power laser beam parameters

N Reng, B Eppich - Optical and quantum electronics, 1992 - Springer
… , the power content profile and the power content area. The methods of measurement are …
suitability for two high-power laser systems: a cw Nd : YAG-rod laser and an annular system. …

Measuring total corneal power before and after laser in situ keratomileusis with high-speed optical coherence tomography

M Tang, Y Li, M Avila, D Huang - Journal of Cataract & Refractive …, 2006 - journals.lww.com
… In this study, we developed 2 methods to measure total corneal power using OCT. To our
knowledge, this is the first demonstration of both the OCT-only and the hybrid OCT–Placido …

High‐power solid‐state lasers: a laser glass perspective

JH Campbell, JS Hayden… - International Journal of …, 2011 - Wiley Online Library
… the needs of the next generation of high-power glass lasers. Examples of promising
glasses and the required manufacturing methods are discussed. Competition from single-crystals …