Optical mapping of human embryonic stem cell-derived cardiomyocyte graft electrical activity in injured hearts

D Filice, W Dhahri, JL Solan, PD Lampe… - Stem cell research & …, 2020 - Springer
D Filice, W Dhahri, JL Solan, PD Lampe, E Steele, N Milani, B Van Biber, WZ Zhu
Stem cell research & therapy, 2020Springer
Background Human embryonic stem cell-derived cardiomyocytes (hESC-CMs) show
tremendous promise for cardiac regeneration, but the successful development of hESC-CM-
based therapies requires improved tools to investigate their electrical behavior in recipient
hearts. While optical voltage mapping is a powerful technique for studying myocardial
electrical activity ex vivo, we have previously shown that intra-cardiac hESC-CM grafts are
not labeled by conventional voltage-sensitive fluorescent dyes. We hypothesized that the …
Background
Human embryonic stem cell-derived cardiomyocytes (hESC-CMs) show tremendous promise for cardiac regeneration, but the successful development of hESC-CM-based therapies requires improved tools to investigate their electrical behavior in recipient hearts. While optical voltage mapping is a powerful technique for studying myocardial electrical activity ex vivo, we have previously shown that intra-cardiac hESC-CM grafts are not labeled by conventional voltage-sensitive fluorescent dyes. We hypothesized that the water-soluble voltage-sensitive dye di-2-ANEPEQ would label engrafted hESC-CMs and thereby facilitate characterization of graft electrical function and integration.
Methods
We developed and validated a novel optical voltage mapping strategy based on the simultaneous imaging of the calcium-sensitive fluorescent protein GCaMP3, a graft-autonomous reporter of graft activation, and optical action potentials (oAPs) derived from di-2-ANEPEQ, which labels both graft and host myocardium. Cardiomyocytes from three different GCaMP3+ hESC lines (H7, RUES2, or ESI-17) were transplanted into guinea pig models of subacute and chronic infarction, followed by optical mapping at 2 weeks post-transplantation.
Results
Use of a water-soluble voltage-sensitive dye revealed pro-arrhythmic properties of GCaMP3+ hESC-CM grafts from all three lines including slow conduction velocity, incomplete host-graft coupling, and spatially heterogeneous patterns of activation that varied beat-to-beat. GCaMP3+ hESC-CMs from the RUES2 and ESI-17 lines both showed prolonged oAP durations both in vitro and in vivo. Although hESC-CMs partially remuscularize the injured hearts, histological evaluation revealed immature graft structure and impaired gap junction expression at this early timepoint.
Conclusion
Simultaneous imaging of GCaMP3 and di-2-ANEPEQ allowed us to acquire the first unambiguously graft-derived oAPs from hESC-CM-engrafted hearts and yielded critical insights into their arrhythmogenic potential and line-to-line variation.
Springer
以上显示的是最相近的搜索结果。 查看全部搜索结果