[PDF][PDF] RFQ with improved energy gain

AS Plastun, AA Kolomiets - Proc. of LINAC12 Conference, 2012 - accelconf.web.cern.ch
… Using conventional RFQ structure for acceleration of particles for higher energies is
impractical because RFQ energy gain decreases rapidly with energy at constant modulation. …

RFQ designs and beam-loss distributions for IFMIF

RA Jameson - 2007 - osti.gov
energy into the RFQ is important. Typically, a lower injection energy results in a shorter RFQ
but other aspects of the RFQ … Lower injection energy results in higher space-charge effect in …

Improved bunching and longitudinal emittance control in an RFQ

RA Jameson, B Yee-Rendon - Journal of Instrumentation, 2022 - iopscience.iop.org
… Quadrupole (RFQ) cell has been applied that significantly improves beam bunching and
longitudinal emittance control to achieve lower longitudinal rms emittance at the RFQ output. …

[PDF][PDF] RFQ's-An Introduction

JW Staples - 1990 - escholarship.org
… The small, compact and reliable RFQ provides operational cost … of the preinjector and
improving access to the ion source. … was gained in operating an RFQ at nearly 100% duty factor. …

A compact high-frequency RFQ for medical applications

M Vretenar, E Montesinos, M Timmins, M Garlaschè… - 2014 - cds.cern.ch
… The angle of the cone is optimized to minimize the losses and improve the sensitivity. Each
… on the experience gained with the Linac4 RFQ and the brazing of other RFQs at CERN. …

[PDF][PDF] RFQ Performance During RF Conditioning and Beam Commissioning at ESS

R Zeng, O Piquet - Proc. 31st Linear Accelerator Conference (LINAC' …, 2022 - inspirehep.net
improvement was also made during subsequent re-conditionings, and the recovery time to
nominal level was improved … to gain insight into system limits and find a way to operate RFQ

Initial Conditioning of the Rod-style RFQ

TW Hall, JTM Lyles, M Sanchez Barrueta, MD Zuboraj - 2023 - osti.gov
… the RFQ. The maximum power output of the amplifier is limited to 160-180 kW by both its gain
… The collection of data was improved when we added a National Instruments cRIO-9045 for …

[PDF][PDF] Design of a Superconducting RFQ resonator

I Ben-Zvi, P Paul, A Lombardi - Part. Accel., 1991 - cds.cern.ch
RFQ linac ("tapering") one can improve the accelerating field in separate RFQ units1 as well
as in a single RFQ … to increase significantly the energy gain of the RFQ linac. We introduce '…

Design of 57.5 MHz cw RFQ for medium energy heavy ion superconducting linac

PN Ostroumov, AA Kolomiets, DA Kashinsky… - Physical Review Special …, 2002 - APS
… The principal specifications of the RFQ are (i) formation of extremely low longitudinal …
RFQ cavity, as well as some aspects of the mechanical design of the low-frequency cw RFQ

Design of a CW BISOL RFQ for Three Kinds of High-Charge-State Ions Simultaneous Acceleration

M Han, Y Lu, Z Wang, Z Peng, S Liu, T Wei, Y Xia - Applied Sciences, 2022 - mdpi.com
… , the energy gain per nucleon of the synchronous particle in an RFQ accelerating cell is [19]: …
It has been proven that the longitudinal output emittance of an RFQ can be improved by …