[HTML][HTML] Comparison of motion artefact reduction methods and the implementation of adaptive motion artefact reduction in wearable electrocardiogram monitoring

X An, G K. Stylios - Sensors, 2020 - mdpi.com
… suitable for reducing motion artefacts in the ECG signal than other signal-processing
methods. In order to discuss the possibility of using adaptive filter for motion artefact reduction in …

Two-stage approach for detection and reduction of motion artifacts in photoplethysmographic data

R Krishnan, B Natarajan… - IEEE transactions on …, 2010 - ieeexplore.ieee.org
… decisions into a global system decision. For stage two, we propose a motion artifact reduction
method that is effective even in the presence of severe subject movement. The approach …

Development of real-time motion artifact reduction algorithm for a wearable photoplethysmography

H Han, MJ Kim, J Kim - … conference of the IEEE engineering in …, 2007 - ieeexplore.ieee.org
… device, and the motion artifact reduced algorithm techniques, described in … motion artifact
reduction algorithm can be integrated as a terminal in a so-called ubiquitous healthcare system

A robust fusion method for motion artifacts reduction in photoplethysmography signal

S Nabavi, S Bhadra - IEEE Transactions on Instrumentation …, 2020 - ieeexplore.ieee.org
… and red), while this motion reduction has no impact on the … by the proposed motion artifacts
reduction method in this work … of the proposed motion artifacts reduction technique, two …

Motion artifact reduction in ambulatory ECG monitoring: an integrated system approach

I Romero, T Berset, D Buxi, L Brown… - Proceedings of the 2nd …, 2011 - dl.acm.org
… a system approach to motion artifact reductionartifact and 3D-acceleration. Beyond ECG
monitoring, this wireless patch provides the additional necessary data to filter out motion artifact

A novel approach for motion artifact reduction in PPG signals based on AS-LMS adaptive filter

MR Ram, KV Madhav, EH Krishna… - IEEE Transactions …, 2011 - ieeexplore.ieee.org
… In addition to arterial oxygen saturation (SpO2) estimation, the artifact reduction method
facilitated the waveform contour analysis on artifact-reduced PPG, and the conventional …

[HTML][HTML] Motion artifact reduction in wearable photoplethysmography based on multi-channel sensors with multiple wavelengths

J Lee, M Kim, HK Park, IY Kim - Sensors, 2020 - mdpi.com
motion artifact reduction algorithm based on the signals obtained through this system.
Using … We present a method by which to reduce motion artifacts through applying ICA and a …

Motion artifact reduction in photoplethysmography using independent component analysis

BS Kim, SK Yoo - IEEE transactions on biomedical engineering, 2006 - ieeexplore.ieee.org
… have been researched to manage the motion artifacts from measured PPG signals [1], [2]. …
of motion artifact rejection. In this paper, the new motion artifact reduction method was …

Motion Artifacts reduction from the PPG based on the Improved PMAF for the U-Healthcare System

HW Lee, JW Lee, WG Jeong, JC Jun… - Journal of the Institute of …, 2008 - koreascience.kr
system we proposed is more affected by the motion artifacts. So to filter this motion artifacts,
we propose the new method; the improved PMAF(Periodic Moving Average Filter) method. …

[HTML][HTML] Methods for motion artifact reduction in online brain-computer interface experiments: a systematic review

M Schmoigl-Tonis, C Schranz… - Frontiers in Human …, 2023 - frontiersin.org
methods for motion artifact reduction in online BCI experiments. Using the PRISMA filter
method… rules to identify existing methods and pipelines for motion artifact reduction in EEG data. …