Day and night home closed-loop insulin delivery in adults with type 1 diabetes: three-center randomized crossover study

L Leelarathna, S Dellweg, JK Mader, JM Allen… - Diabetes …, 2014 - Am Diabetes Assoc
temporary reductions or increments of basal insulin delivery to … percentage of time spent in
target glucose range 3.9–10.0 mmol… stay and fully recovered with intravenous fluid treatment. …

Review of the Omnipod® 5 Automated Glucose Control System Powered by Horizon™ for the Treatment of Type 1 Diabetes

EC Cobry, C Berget, LH Messer… - Therapeutic Delivery, 2020 - Taylor & Francis
… maintain the programmed target glucose value in its insulin … temporary reduction in basal
insulin delivery during exercise. … measures glucose values every 5 min in the interstitial fluid

Six months of hybrid closed-loop versus manual insulin delivery with fingerprick blood glucose monitoring in adults with type 1 diabetes: a randomized, controlled trial

SA McAuley, MH Lee, B Paldus, S Vogrin… - Diabetes …, 2020 - Am Diabetes Assoc
Target glucose is 120 mg/dL, with an optional increased temporary target of 150 mg/dL. Either
… This TIR difference was achieved by reductions in time above and below predefined high …

Sick day management in children and adolescents with diabetes

H Phelan, R Hanas, SE Hofer, S James… - Pediatric …, 2022 - Wiley Online Library
… , carbohydrate-containing liquids if glucose level is below 14 … is a concern, as a temporary
basal rate reduction for 2–4 h or … helpful to keep the glucose levels in target during sick days. …

The competitive athlete with type 1 diabetes

MC Riddell, SN Scott, PA Fournier, SR Colberg… - Diabetologia, 2020 - Springer
… The latter allows for temporary basal rate reductions in … exercise if a temporary (higher)
glucose target is set well before … Fluid intake during training tends to be higher in type 1 diabetes, …

[PDF][PDF] Continuous subcutaneous insulin infusion: a local perspective

TTL Yau, AJ Jenkins, RCW Ma - … Kong medical journal= Xianggang yi xue …, 2023 - hkmj.org
glucose monitoring tracks interstitial fluid glucose level for 7 … - or caregiver-initiated higher
temporary target (eg, 8.3 mmol/… time in range (TIR) and decreases glucose variability. A meta-…

Emerging diabetes technologies: continuous glucose monitors/artificial pancreases

AM Almurashi, E Rodriguez, SK Garg - Journal of the Indian Institute of …, 2023 - Springer
… the patients and providers (temporarily, even across different States … overall glucose control,
especially reducing overnight … (EASD) target of glucose control (< 7%) as measured by A1c. …

Optimizing insulin pump therapy: a quality improvement project

LT Meade, WE Rushton - The Diabetes Educator, 2013 - journals.sagepub.com
… and blood glucose levels, alternate bolus delivery options, variable … amount for all blood
glucose levels over target Y/N … of the pump were the temporary basal increase and decrease. …

Therapeutics of diabetes mellitus: focus on insulin analogues and insulin pumps

V Valla - Journal of Diabetes Research, 2010 - Wiley Online Library
… in a substantial decline in fasting glucose and HbA1C, with … needle in the abdomen for
temporary pump interruption [44, 45]… based on fluctuations from the target glucose level. Individual …

New technologies in insulin delivery

MJ Taylor, TS Sahota - Practical Diabetes, 2013 - Wiley Online Library
… reading not blood glucose but interstitial fluid values. Since it … /h respectively with temporary
basal rate reductions available to … , and present and target glucose levels. Electronic systems …