[HTML][HTML] Testing hadronic interaction models using a highly granular silicontungsten calorimeter

B Bilki, J Repond, J Schlereth, L Xia, Z Deng… - Nuclear Instruments and …, 2015 - Elsevier
test and to further develop models of hadronichighly granular silicontungsten electromagnetic
calorimeter prototype (Si–W ECAL) prototype [6] is used to test hadronic shower models

Testing hadronie interaction models using a highly granular silicon-tungsten calorimeter

N van der Kolk - 2015 IEEE Nuclear Science Symposium and …, 2015 - ieeexplore.ieee.org
… are very detailed probes of the hadronic shower models used in the simulation. For the first
… in the interaction zone and the number of tracks that emerge from the interaction zone for …

IEEE: Testing hadronie interaction models using a highly granular silicon-tungsten calorimeter

N van der Kolk - 2015 - cds.cern.ch
… are very detailed probes of the hadronic shower models used in the simulation. For the first
… in the interaction zone and the number of tracks that emerge from the interaction zone for …

Low-energetic hadron interactions in a highly granular calorimeter

N Feege - 2011 - inis.iaea.org
test-beam programs at DESY, CERN, and Fermilab since 2005. The focus of this dissertation
is on the prototype for a hadron calorimeter … a silicon-tungsten electromagnetic calorimeter (…

Hadronic models validation in GEANT4 with CALICE highly granular calorimeters

M Ramilli, CALICE collaboration - Journal of Physics …, 2012 - iopscience.iop.org
calorimeter is a sampling structure of tungsten and silicon with … In this paper data taken in
2007 in the CERN H6 test beam … First hadronic interaction The high granularity of the CALICE …

Hadrons in a highly granular silicon-tungsten electromagnetic calorimeter-Top quark production at the International Linear Collider

P Doublet - 2011 - inis.iaea.org
test beams of a prototype of a highly granular silicon-tungsten electromagnetic calorimeter
(… Carlo simulations in order to improve models of hadronic interactions. On the other hand, the …

Towards precision time and energy measurements in highly granular hadronic calorimeters

C Graf - 2020 - mediatum.ub.tum.de
… is to explore and test various technologies to realize such a calorimeter. The focus … calorimeter
using a steel or tungsten absorber. The active components are scintillators with a Silicon

Highly granular calorimeters: technologies and results

Y Liu - Journal of Instrumentation, 2017 - iopscience.iop.org
… of hadronic showers using highly granular calorimeters also … hadronic showers and to finely
test shower models. The response of the Silicon-Tungsten ECAL to first hadronic interactions

[PDF][PDF] Time development of hadronic showers in a Highly Granular Analog Hadron Calorimeter

E Brianne - 2018 - bib-pubdb1.desy.de
… -based hadron calorimeter using Silicon photomultiplier (SiPM… of the Higgs Boson properties
for example by exploiting the H … interaction length) using Tungsten as absorbing material is …

CALICE highly granular calorimeters: imaging properties for hadronic shower analysis

M Chadeeva - Journal of Instrumentation, 2020 - iopscience.iop.org
… scintillator strips read out by silicon photomultipliers (SiPM), … by the effective nuclear interaction
length of the calorimeter in … 10 GeV mixed test beam in the CALICE AHCAL with tungsten