Time-resolved heat transfer measurements on the tip wall of a ribbed channel using a novel heat flux sensor—Part I: Sensor and benchmarks

T Roediger, H Knauss, U Gaisbauer, E Kraemer… - 2008 - asmedigitalcollection.asme.org
… Furthermore, the time-resolved measurements and the spectral data are … as a novel heat
flux sensor with unique properties. It allows for highly time-resolved heat flux measurements up …

Time-resolved heat transfer measurements on the tip wall of a ribbed channel using a novel heat flux sensor—part II: Heat transfer results

S Jenkins, J von Wolfersdorf, B Weigand… - 2008 - asmedigitalcollection.asme.org
… these secondary flows on the tip-wall heat transfer have not. This … to mean heat transfer
distributions and time-resolved results. … heat transfer on the tip wall of a high aspect ratio channel

Time-Resolved Heat Transfer Measurements on the Tip Wall of a Ribbed Channel Using a Novel Heat Flux Sensor: Part II—Heat Transfer Results

S Jenkins, J von Wolfersdorf… - … Expo: Power for …, 2006 - asmedigitalcollection.asme.org
… these secondary flows on the tip wall heat transfer have not. This … to mean heat transfer
distributions and time-resolved results. … heat transfer on the tip wall of a high aspect ratio channel

Time-Resolved Heat Transfer Measurements on the Tip Wall of a Ribbed Channel Using a Novel Heat Flux Sensor: Part I—Sensor and Benchmarks

T Roediger, H Knauss… - … Expo: Power for …, 2006 - asmedigitalcollection.asme.org
… The Atomic Layer Thermopile (ALTP) has been introduced in this paper as a novel heat flux
sensor with unique properties. It allows for highly time-resolved heat flux measurements up …

The effects of ribs and tip wall distance on heat transfer for a varying aspect ratio two-pass ribbed internal cooling channel

SC Jenkins, F Zehnder… - Journal of …, 2013 - asmedigitalcollection.asme.org
… resolved heat transfer measurements were made using the … indication and a local time-resolved
bulk temperature profile, … the story drastically changes for the bend region and tip wall. …

Time-resolved PIV measurement and thermal-hydraulic performance evaluation of thin film self-agitators in a rectangular channel flow

S Wang, K Li, Z Ke, CL Chen - … Journal of Heat and Mass Transfer, 2019 - Elsevier
… to explore the heat transfer mechanism of the channel flow. … Results show that turbulence
is generated along the tip of … designs compared to a plain wall benchmark. The main tasks …

Spatio-temporal analysis of the turbulent flow in a ribbed channel

F Coletti, I Cresci, T Arts - International journal of heat and fluid flow, 2013 - Elsevier
… of enhancing the heat transfer from the hot walls to the coolant … and the time-resolved
measurements. Conclusions are … layer which is created on the rib tip: this grows in thickness with …

The effect of ribs and tip wall distance on heat transfer for a varying aspect ratio two-pass ribbed internal cooling channel

SC Jenkins, F Zehnder… - … Expo: Power for …, 2008 - asmedigitalcollection.asme.org
… resolved heat transfer measurements were made using the … indication and a local time-resolved
bulk temperature profile, … the story drastically changes for the bend region and tip wall. …

Experimental heat transfer and flow simulations of rectangular channel with twisted-tape pin-fin array

SW Chang, PS Wu, WL Cai, CH Yu - … Journal of Heat and Mass Transfer, 2021 - Elsevier
… Ostanek and Thole [2] adopted time-resolved particle image … when the dimensionless pin-tip
clearance was less than 0.2. … is the local wall temperature measured in the heat transfer test …

Experimental study of turbulent flow and heat transfer behaviors over a micro-rib-dimple-structured surface

K Zheng, W Tian, P Zhang… - Journal of …, 2021 - asmedigitalcollection.asme.org
… Ligrani [4] experimentally measured the channel heat transfer … [24,25] combined the angled
rib and dimple as a novel rib-… the wall temperature T w were obtained by TLC measurements. …