optical Kerr coefficients of materials. An empirical expression is obtained which allows direct
calculation of the Kerr coefficient from measured peak–valley transmittance differences.
Predictions of the model are compared with Z‐scan measurement on CS2. Using top‐hat
beams, the sensitivity of Z‐scan measurements is a factor of 2.5 greater than for Gaussian
beams.