based ion-selective potentiometric sensors

M Novell, M Parrilla, GA Crespo, FX Rius… - Analytical …, 2012 - ACS Publications
… -based potentiometric sensors, which, to the best of our knowledge, has not yet been
explored. In this report, the development of solid contact ISEs based on … PVC based ion-selective

Ionophore-based ion-selective potentiometric and optical sensors

RD Johnson, LG Bachas - Analytical and bioanalytical chemistry, 2003 - Springer
… Other advances are broadening the use of ion sensors in a … A majority of the work in
ionophore-based sensors, however, … the field of ion-selective sensors and ionophore …

Screening highly selective ionophores for heavy metal ion-selective electrodes and potentiometric sensors

L Sun, C Sun, X Sun - Electrochimica Acta, 2016 - Elsevier
… to discover new ionophores used in ion-selective electrodes (ISEs). … -based polymeric
membrane heavy metal ion-selective … for other ionophore-based ISEs and potentiometric sensors. …

Polymer membrane-based ion-, gas-and bio-selective potentiometric sensors

HS Yim, CE Kibbey, SC Ma, DM Kliza, D Liu… - Biosensors and …, 1993 - Elsevier
ion-selective membranes as transducers in the design of various types of bioanalytical
sensors, ranging from simple ion sensors to more complex enzyme- and antibodybased probes, …

Ion-selective potentiometric sensors with silicone sensing membranes: A review

XV Chen, P Bühlmann - Current Opinion in Electrochemistry, 2022 - Elsevier
Potentiometric sensors have become an integral part of wearable devices to monitor key …
A key aspect of the development of wearable and implantable potentiometric sensor is …

A Copper(II) IonSelective Potentiometric Sensor Based on N,N′,N″,N′′′‐Tetrakis(2‐pyridylmethyl)‐1,4,8,11‐tetraazacyclotetradecane in PVC Matrix

BB Petković, SP Sovilj, MV Budimir… - …, 2010 - Wiley Online Library
… A several ion-selective electrodes based on aza macrocycles … study to develop ion selective
Cu(II) electrode based on tpmc ligand … In order to obtain further insight into the potentiometric

Determination of lactate levels in biological fluids using a disposable ion-selective potentiometric sensor based on polypyrrole films

P Mengarda, FAL Dias, JVC Peixoto, R Osiecki… - Sensors and Actuators B …, 2019 - Elsevier
potentiometric sensor based on PPy films (PPy:LAC) for estimation of lactate levels in different
biological samples. The strategy was based … versatile ion-selective potentiometric sensor

Calibration-free potentiometric sensing with solid-contact ion-selective electrodes

CR Rousseau, P Bühlmann - TrAC Trends in Analytical Chemistry, 2021 - Elsevier
… is not a primary characteristic of a sensor, reporting of the reproducibility of E 0 is a metric
important for comparing the performance of different potentiometric sensing systems. For those …

Selectivity comparison of neutral carrier-based ion-selective optical and potentiometric sensing schemes

E Bakker - Analytica chimica acta, 1997 - Elsevier
… -based ion-selective electrode membranes and corresponding … of the mixed ion response of
carrier-based ion-selective … use today to characterize the selectivity of carrier-based sensors. …

Polymer-based cadmium(II)-selective potentiometric sensors for the analysis of Cd2+ in different environmental samples

O Özbek, Ö Isildak - International Journal of Environmental …, 2023 - Taylor & Francis
Potentiometric sensors were first described by Cremer [… Potentiometry based ion-selective
electrodes or sensors have many … Potentiometric measurement system is based on the …