Opposite clear corneal incisions to correct pre-existing astigmatism in cataract surgery

J Lever, E Dahan - Journal of Cataract & Refractive Surgery, 2000 - journals.lww.com
… axis was marked and the steepest meridian identified using an astigmatic marker. Two …
Our technique uses the well-known corneal flattening effect of penetrating CCIs to modulate …

Controlling astigmatism in cataract surgery

DD Koch, RL Lindstrom - Seminars in ophthalmology, 1992 - Taylor & Francis
… patients whose astigmatism exceeds 2 D and whose fellow eye: (… We discuss the rationale,
surgical methods, and risks with the … Katena-Lindstrom arcuate marker is placed on cornea

[引用][C] … for corneal marking for Toric IOL implantation and a comparative series of 60 eyes comparing the results of the new and conventional marking techniques

BR Chaudhuri, M Barishan, R Krishnan - Medicine, 2014

Paired opposite clear corneal incisions to correct preexisting astigmatism in cataract patients

A Qammar, P Mullaney - Journal of Cataract & Refractive Surgery, 2005 - Elsevier
… while the axis of astigmatism was marked to avoid torsional … This method 3 of correcting
astigmatism usually involves … on the degree of astigmatism made on the steep corneal axis. …

New method of targeting vectors to treat astigmatism

NA Alpins - Journal of Cataract & Refractive Surgery, 1997 - journals.lww.com
… on eliminating astigmatism from the eye's optical system. … to the expected corneal astigmatism
resulting from surgery where … In reality, however, there are marked differences between the …

… and corneal astigmatism correction during cataract surgery: aspheric toric intraocular lens versus aspheric nontoric intraocular lens with opposite clear corneal …

S Maedel, N Hirnschall, YA Chen, O Findl - Journal of Cataract & Refractive …, 2014 - Elsevier
… Inaccurate preoperative marking due to cyclotorsion of the eye with the patient supine, …
An alternative method to reduce corneal astigmatism as part of cataract surgery is to make …

Comparability of an image-guided system with other instruments in measuring corneal keratometry and astigmatism

M Schultz, U Oberheide, O Kermani - Journal of Cataract & Refractive …, 2016 - Elsevier
methods have been developed to measure keratometry (K) and determine corneal astigmatism,
… might compare other registration techniques, such as the manual gravity-based marker

Comparison of clinical outcomes among 3 marking methods for toric intraocular lens implantation

H Onishi, H Torii, K Watanabe, K Tsubota… - Japanese journal of …, 2016 - Springer
… alignment and the visual and refractive outcomes of 3 marking methods according to the
preoperative corneal astigmatic axes and evaluated manual marking for toric IOL implantation. …

Five-year changes in corneal astigmatism after combined femtosecond-assisted phacoemulsification and arcuate keratotomy

TCY Chan, ALK Ng, Z Wang, JSM Chang… - American Journal of …, 2020 - Elsevier
… the stability of corneal astigmatism over time. The current study was a follow-up study of corneal
astigmatism after … The marking and alignment technique has been published previously. …

Adjustment of anterior corneal astigmatism values to incorporate the likely effect of posterior corneal curvature for toric intraocular lens calculation

M Goggin, K Zamora-Alejo… - Journal of Refractive …, 2015 - journals.healio.com
… or undercorrection of corneal astigmatism based on the “rule” of the astigmatism in patients
with … The vertical corneal meridian was marked preoperatively using a technique previously …