Finite element assessment of moving coil actuator for HVDC breaker applications

DS Vilchis-Rodriguez, R Shuttleworth… - IECON 2016-42nd …, 2016 - ieeexplore.ieee.org
This paper assesses the suitability of the moving coil actuator for use as an ultra-fast, long
stroke linear drive for HVDC breaker applications. With the help of FEA, a sensitivity analysis …

Drive circuits for ultra-fast and reliable actuation of Thomson coil actuators used in hybrid AC and DC circuit breakers

C Peng, A Huang, I Husain… - 2016 IEEE Applied …, 2016 - ieeexplore.ieee.org
Thomson coil actuators (also known as repulsion coil actuators) are well suited for vacuum
circuit breakers when fast operation is desired such as for hybrid AC and DC circuit breaker …

Analysis and design of a Thomson coil actuator system for an HVDC circuit breaker

MS Sim, SSH Bukhari, JS Ro - IEEE Access, 2022 - ieeexplore.ieee.org
In this study, we analyze and design a Thomson coil actuator system (TCAS) that ensures
stable operation of a high voltage direct current circuit breaker. High voltage direct current …

Reduced-time finite element model for Thomson coil actuator

M Al-Dweikat, W Wen, Y Huang, G Zhang… - Electric Power …, 2022 - Taylor & Francis
With the rapid development of DC systems and the increasing demand for DC circuit
breakers, electromagnetic repulsive drive-based Thomson coil actuators (TCAs) are widely …

A review on Thomson coil actuators in fast mechanical switching

M Al-Dweikat, J Cui, S Sun, M Yang, G Zhang, Y Geng - Actuators, 2022 - mdpi.com
With the rapid development of DC power systems and the increasing demand for DC circuit
breakers, electromagnetic repulsive drives-based Thomson coil actuators (TCA) are widely …

Design and analysis of double-sided Thomson coil actuator for extra fast opening operation

A Al-Qarni, ELR Ayman - 2021 IEEE Energy Conversion …, 2021 - ieeexplore.ieee.org
Thomson Coil Actuator (TCA) has gained increased research interests in recent years due to
the fast response as well as manageable losses. Therefore, this paper presents the design …

Modeling and verification of ultra-fast electro-mechanical actuators for HVDC breakers

A Bissal - 2015 - diva-portal.org
The continuously increasing demand for clean renewable energy has rekindled interest in
multi-terminal high voltage direct current (HVDC) grids. Although such grids have several …

Comparison of damping techniques for the soft‐stop of ultra‐fast linear actuators for HVDC breaker applications

DS Vilchis‐Rodriguez, R Shuttleworth… - The Journal of …, 2019 - Wiley Online Library
This paper assesses the advantages, drawbacks, and overall suitability of different soft‐stop
techniques to provide smooth deceleration of ultra‐fast linear actuators used in hybrid …

Electric to mechanical energy conversion of linear ultrafast electromechanical actuators based on stroke requirements

A Bissal, J Magnusson… - IEEE Transactions on …, 2015 - ieeexplore.ieee.org
The operational efficiency of ultrafast actuators used as drives in high-voltage direct-current
breakers is at best 5%. To boost their efficiency, the design of the energizing circuit is crucial …

Dynamic analysis of Thomson coil actuator for fast switch of HVDC circuit breaker

SH Park, HJ Jang, JK Chong… - 2015 3rd International …, 2015 - ieeexplore.ieee.org
In this paper, the analysis is performed on Thomson coil actuator and the dynamic
characteristics is presented, which is necessary to the fast switch of HVDC circuit breaker …