Maximum mass flow ratio due to secondary flow choking in an ejector refrigeration system

SK Chou, PR Yang, C Yap - International journal of refrigeration, 2001 - Elsevier
The occurrence of flow choking in an ejector of an ejector refrigeration system (ERS) was
analysed and a model for predicting the maximum flow ratio of the ejector was developed …

[HTML][HTML] Thermodynamic modelling and parameter determination of ejector for ejection refrigeration systems

Z Ma, H Bao, AP Roskilly - international journal of refrigeration, 2017 - Elsevier
This paper presents a detailed thermodynamic modelling method of an ejector for ejection
refrigeration system. In this model, the primary flow in the ejector was assumed to fan out …

Parametric analysis of ejector working characteristics in the refrigeration system

J Chen, H Havtun, B Palm - Applied Thermal Engineering, 2014 - Elsevier
A detailed investigation of ejector working characteristics in terms of refrigeration efficiency,
ejector entrainment ratio, and irreversibilities in each ejector component (nozzle, mixing …

One dimensional model of an ejector with special attention to Fanno flow within the mixing chamber

NS Kumar, KT Ooi - Applied thermal engineering, 2014 - Elsevier
Ejector refrigeration systems are less power intensive when compared to conventional
refrigeration cycles, mainly due to their ability to use low-grade heat sources to reduce …

A 1-D analysis of ejector performance

BJ Huang, JM Chang, CP Wang… - International journal of …, 1999 - Elsevier
A 1-D analysis for the prediction of ejector performance at critical-mode operation is carried
out in the present study. Constant-pressure mixing is assumed to occur inside the constant …

Simulation of an ejector used in refrigeration systems

M Elakhdar, E Nehdi, L Kairouani, N Tounsi - International journal of …, 2011 - Elsevier
The present study describes a computer simulation model for refrigerant ejector. A one-
dimensional mathematical model was developed using the equations governing the flow …

Investigation of ejectors in refrigeration system: Optimum performance evaluation and ejector area ratios perspectives

J Chen, H Havtun, B Palm - Applied Thermal Engineering, 2014 - Elsevier
This paper presents an ejector model to determine the optimum performance as well as
obtaining the design area ratio of an ejector in a refrigeration system. Working fluid …

Experimental determination of the optimum performance of ejector refrigeration system depending on ejector area ratio

R Yapıcı, HK Ersoy, A Aktoprakoğlu, HS Halkacı… - International journal of …, 2008 - Elsevier
The performance of the ejector refrigeration system using ejectors with cylindrical mixing
chamber is studied at operating conditions with choking in the mixing chamber. The …

A comprehensive review of ejector design, performance, and applications

BM Tashtoush, AN Moh'd A, MA Khasawneh - Applied Energy, 2019 - Elsevier
The objective of this work is to provide a literature survey on the research attempts made in
the field of ejector refrigeration systems and the studies made on the ejector as a …

CFD analysis of ejector in a combined ejector cooling system

E Rusly, L Aye, WWS Charters, A Ooi - International Journal of Refrigeration, 2005 - Elsevier
One-dimensional ejector analyses often use coefficients derived from experimental data for
a set of operating conditions with limited functionality. In this study, several ejector designs …