Active control of pressure oscillations in a liquid-fueled sector combustor

JM Cohen, A Banaszuk, JR Hibshman, TJ Anderson… - 2008 - asmedigitalcollection.asme.org
Emphasis on reducing the levels of pollutants created by gas turbine combustors has led to
the development of lean, premixed combustor designs, especially for industrial applications …

[图书][B] Combustion oscillation control by cyclic fuel injection

GA Richards, MJ Yip, E Robey, L Cowell, D Rawlins - 1995 - asmedigitalcollection.asme.org
A number of recent articles have demonstrated the use of active control to mitigate the
effects of combustion instability in afterburner and dump combustor applications. In these …

Combustion oscillation control by cyclic fuel injection

GA Richards, MJ Yip, E Robey, L Cowell, D Rawlins - 1997 - asmedigitalcollection.asme.org
A number of recent articles have demonstrated the use of active control to mitigate the
effects of combustion instability in afterburner and dump combustor applications. In these …

Active control of combustion instability in a liquid-fueled low-nox combustor

JM Cohen, NM Rey, CA Jacobson, TJ Anderson - 1999 - asmedigitalcollection.asme.org
A practical active control system for the mitigation of combustion instability has been
designed and demonstrated in a lean, premixed, single-nozzle combustor at realistic engine …

[图书][B] An experimental and theoretical investigation of a fuel system tuner for the suppression of combustion driven oscillations

DE Scarborough - 2010 - search.proquest.com
Manufacturers of commercial, power-generating, gas turbine engines continue to develop
combustors that produce lower emissions of nitrogen oxides (NO x) in order to meet the …

[图书][B] Causes of combustion instabilities with passive and active methods of control for practical application to gas turbine engines

MD Cornwell - 2011 - search.proquest.com
Combustion at high pressure in applications such as rocket engines and gas turbine
engines commonly experience destructive combustion instabilities. These instabilities …

Combustion instability suppression in liquid-fueled combustors

K McManus, J Magill, M Miller - 36th AIAA Aerospace Sciences Meeting …, 1998 - arc.aiaa.org
A study has been performed to evaluate the effectiveness of a closed-loop control system to
suppress thermo-acoustic combustion instabilities. The pulsewidth modulation technique …

CFD assessment of passive and active control strategies for lean, premixed combustors

C Smith - 37th Aerospace Sciences Meeting and Exhibit, 1999 - arc.aiaa.org
CFD-based combustion dynamics modeling is used to study the effect of fuel injection
location and fuel flow modulation on combustion instability in lean, premixed combustors …

Dynamics Suppression in Liquid-Fueled Combustors Using Fuel Modulation

Z Hong, JM Haynes, JT Herbon… - … Expo: Power for …, 2012 - asmedigitalcollection.asme.org
In the present work, an atmospheric pressure combustor using a modern aviation gas
turbine fuel nozzle was used to demonstrate active combustion control. The combustor …

Active control of combustion dynamics for lean premixed gas fired systems

B Anson, I Critchley… - … Expo: Power for …, 2002 - asmedigitalcollection.asme.org
The present paper describes an active control system consisting of a fast-acting actuator
valve, coupled with a control algorithm capable of adaptive phase and amplitude control for …