Scanning electrochemical microscopy: theory and application of the transient (chronoamperometric) SECM response

AJ Bard, G Denuault, RA Friesner… - Analytical …, 1991 - ACS Publications
Previous papers have described the theory (1-3) and ap-plications (4-12) of the scanning
electrochemical microscope (SECM) operating in the steady-state current regime. The tip …

Scanning electrochemical microscopy. Theory of the feedback mode

J Kwak, AJ Bard - Analytical Chemistry, 1989 - ACS Publications
The steady-state current that flows between the scanning tip (a disk ultramicroelectrode
Imbedded In an Insulating sheath) and a planar sample substrate In a scanning …

Scanning electrochemical microscopy. 57. SECM tip voltammetry at different substrate potentials under quasi-steady-state and steady-state conditions

CG Zoski, CR Luman, JL Fernandez… - Analytical chemistry, 2007 - ACS Publications
We discuss SECM tip voltammetry, where a UME tip is held above a conductive substrate
within about a tip radius and a tip voltammogram is recorded as its potential is slowly …

Scanning electrochemical microscopy. 9. Theory and application of the feedback mode to the measurement of following chemical reaction rates in electrode …

PR Unwin, AJ Bard - The Journal of Physical Chemistry, 1991 - ACS Publications
Theory for the problem, relating the SECM feedbackcurrent to the tip-substrate distance, tip
electrode radius, and rate constant for the chemical step, is developed numerically by …

Scanning electrochemical microscopy. 46. Shielding effects on reversible and quasireversible reactions

CG Zoski, JC Aguilar, AJ Bard - Analytical chemistry, 2003 - ACS Publications
An approximate theory for the feedback mode of the scanning electrochemical microscope
(SECM) is developed to interpret the effects of substrate shielding on an ultramicroelectrode …

Scanning electrochemical microscopy. Introduction and principles

AJ Bard, FRF Fan, J Kwak, O Lev - Analytical Chemistry, 1989 - ACS Publications
The technique of scanningelectrochemical microscopy (SECM) Is described. In this
technique the electrolysis current that flows as an ultramicroelectrode tip (diameter ca. 10 …

[PDF][PDF] Scanning electrochemical microscopy

TF Current - J. Electrochem. Soc, 1991 - bard.cm.utexas.edu
The dependence of the SECM feedback current on finite heterogeneous electron-transfer
(et) kinetics at the substrate electrode was examined by experimental studies of the redu …

Scanning electrochemical microscopy: preparation of submicrometer electrodes

C Lee, CJ Miller, AJ Bard - Analytical chemistry, 1991 - ACS Publications
INTRODUCTION In scanning electrochemical microscopy (SECM), a micro-voltammetric tip
electrode (eg, microdisk geometry with a tip radius of the order of micrometers) is rastered in …

Scanning electrochemical microscopy: VII. Effect of heterogeneous electron‐transfer rate at the substrate on the tip feedback current

DO Wipf, AJ Bard - Journal of the Electrochemical Society, 1991 - iopscience.iop.org
The dependence of the SECM feedback current on finite heterogeneous electron-transfer
(et) kinetics at the substrate electrode was examined by experimental studies of the …

Scanning electrochemical microscopy. 15. Improvements in imaging via tip-position modulation and lock-in detection

DO Wipf, AJ Bard - Analytical Chemistry, 1992 - ACS Publications
In this paper we describe tip-position modulationscanning electrochemical microscopy (TPM
SECM), a new mode of operation of the scanning electrochemical microscope (SECM) …