A 1D model to predict ejector performance at critical and sub-critical operational regimes

WX Chen, M Liu, DT Chong, JJ Yan, AB Little… - International journal of …, 2013 - Elsevier
This paper proposes a new 1D model to predict ejector performance at critical and sub-
critical operational modes, while most previous 1D models have only predicted ejector …

A 1-D analysis of ejector performance

BJ Huang, JM Chang, CP Wang… - International journal of …, 1999 - Elsevier
A 1-D analysis for the prediction of ejector performance at critical-mode operation is carried
out in the present study. Constant-pressure mixing is assumed to occur inside the constant …

One dimensional model of an ejector with special attention to Fanno flow within the mixing chamber

NS Kumar, KT Ooi - Applied thermal engineering, 2014 - Elsevier
Ejector refrigeration systems are less power intensive when compared to conventional
refrigeration cycles, mainly due to their ability to use low-grade heat sources to reduce …

Investigation of ejectors in refrigeration system: Optimum performance evaluation and ejector area ratios perspectives

J Chen, H Havtun, B Palm - Applied Thermal Engineering, 2014 - Elsevier
This paper presents an ejector model to determine the optimum performance as well as
obtaining the design area ratio of an ejector in a refrigeration system. Working fluid …

Performance analysis and optimization of an ejector refrigeration system using alternative working fluids under critical and subcritical operation modes

A Mwesigye, SB Dworkin - Energy conversion and management, 2018 - Elsevier
Ejector systems are receiving considerable attention due to their simplicity, lower
maintenance requirements, use of low grade heat, longer lifespan and low cost. In this paper …

Parametric analysis of ejector working characteristics in the refrigeration system

J Chen, H Havtun, B Palm - Applied Thermal Engineering, 2014 - Elsevier
A detailed investigation of ejector working characteristics in terms of refrigeration efficiency,
ejector entrainment ratio, and irreversibilities in each ejector component (nozzle, mixing …

Investigation of an experimental ejector refrigeration machine operating with refrigerant R245fa at design and off-design working conditions. Part 2. Theoretical and …

KO Shestopalov, BJ Huang, VO Petrenko… - international journal of …, 2015 - Elsevier
The main results of a theoretical and experimental investigation of the performance
characteristics of an ejector and an ejector refrigeration machine (ERM) operating with …

CFD analysis of ejector in a combined ejector cooling system

E Rusly, L Aye, WWS Charters, A Ooi - International Journal of Refrigeration, 2005 - Elsevier
One-dimensional ejector analyses often use coefficients derived from experimental data for
a set of operating conditions with limited functionality. In this study, several ejector designs …

A predictive model for the performance of the ejector in refrigeration system

J Liu, L Wang, L Jia - Energy Conversion and Management, 2017 - Elsevier
Ejectors are widely used in the refrigeration system and the evaluation of the ejector
performance is important for the refrigeration system real time control. In this paper, a simple …

Multi-scale evaluation of ejector performances: The influence of refrigerants and ejector design

G Besagni, N Cristiani, L Croci, GR Guédon… - Applied Thermal …, 2021 - Elsevier
Ejector refrigeration systems pose a promising alternative to vapour compressor
technologies. Still, they have not been penetrating the market because of the strong …