Performance-based seismic design and assessment of multi-storey CFS strap-braced frames

I Papargyriou, I Hajirasouliha - Engineering Structures, 2022 - Elsevier
Cold-formed steel (CFS) structures typically rely on diagonally braced stud walls to
withstand lateral forces. While the response of CFS single-wall panels has been extensively …

More efficient design of CFS strap-braced frames under vertical and seismic loading

I Papargyriou, I Hajirasouliha - Journal of Constructional Steel Research, 2021 - Elsevier
Strap-braced stud walls are one of the primary lateral-force resisting systems for
conventional cold-formed steel (CFS) buildings. While CFS wall-panels in general exhibit a …

Performance-based assessment of CFS strap-braced stud walls under seismic loading

I Papargyriou, I Hajirasouliha, J Becque… - Journal of Constructional …, 2021 - Elsevier
The use of cold-formed steel (CFS) systems has significantly increased in the past few
decades, especially in the construction of low to mid-rise buildings. Compared to hot-rolled …

[PDF][PDF] Performance-based evaluation of strap-braced cold-formed steel frames using incremental dynamic analysis

MR Davani, S Hatami, A Zare - Steel and Composite Structures, 2016 - scholar.archive.org
This study is an effort to clearly recognize the seismic damages occurred in strap-braced
cold formed steel frames. In order to serve this purpose, a detailed investigation was …

Seismic design method for CFS diagonal strap-braced stud walls: Experimental validation

L Fiorino, O Iuorio, V Macillo… - Journal of Structural …, 2016 - ascelibrary.org
The search for innovative methods to ensure high structural, technological, and
environmental performance is an important issue in the development of new construction …

Parametric study on seismic response modification factor of strap-braced cold-formed steel systems

M Abbasi, HT Riahi, M Zeynalian, MY Rahnama - Structures, 2024 - Elsevier
While cold-formed steel structures have been extensively studied for seismic-resistant
construction, existing regulations, and implementation guidelines do not comprehensively …

[PDF][PDF] Inelastic performance and design of cfs walls braced with straps having reduced width fuses

K Velchev, N Balh - 2008 - scholarsmine.mst.edu
Provisions that address the seismic design of cold-formed steel frame strap braced walls are
not provided in the 2005 National Building Code of Canada (NBCC) or in the Canadian …

[HTML][HTML] Experimental investigation on seismic performance of cold-formed steel strap-braced stud walls under lateral cyclic and vertical loading

PL Rad, C Clifton, J Lim, I Hajirasouliha - Thin-Walled Structures, 2024 - Elsevier
Cold-formed steel (CFS) construction offers several benefits over traditional construction,
including being lightweight, sustainable, recyclable, quick to build, insect and rot-resistant …

Seismic performance of CFS strap-braced walls using capacity-based design approach

S Kasaeian, N Usefi, H Ronagh, S Dareshiry - Journal of Constructional …, 2020 - Elsevier
Cold-formed steel (CFS) regulations follow capacity-based design approach to ensure that
the strap braces act as a ductile element in a seismic force-resisting system. In this paper …

Numerical investigation of Australasian cold-formed steel strap-braced walls under lateral and vertical load

A Karmakar, C Clifton, PBP Lim - 2023 - repo.nzsee.org.nz
Cold-Formed Steel (CFS) gained popularity in residential buildings due to its dimensional
accuracy, lightweight, resistance to shrinking and creeping, durability, low embodied carbon …