Simultaneous 10 kHz three-dimensional CH2O and tomographic PIV measurements in a lifted partially-premixed jet flame

B Zhou, T Li, JH Frank, A Dreizler, B Böhm - Proceedings of the …, 2021 - Elsevier
Abstract High-speed, three-dimensional (3D) scalar-velocity field measurements are
demonstrated in a lifted partially-premixed dimethyl-ether/air jet flame using simultaneous …

Simultaneous three-component PIV/OH-PLIF measurements of a turbulent lifted, C3H8-Argon jet diffusion flame at 1.5 kHz repetition rate

I Boxx, C Heeger, R Gordon, B Böhm, M Aigner… - Proceedings of the …, 2009 - Elsevier
Planar laser-induced fluorescence (PLIF) and stereoscopic particle image velocimetry (PIV)
were simultaneously applied at 1.5 kHz repetition-rate to acquire time-resolved …

Simultaneous 10 kHz TPIV, OH PLIF, and CH2O PLIF measurements of turbulent flame structure and dynamics

JR Osborne, SA Ramji, CD Carter, S Peltier… - Experiments in …, 2016 - Springer
Simultaneous 10 kHz repetition-rate tomographic particle image velocimetry, hydroxyl
planar laser-induced fluorescence (OH PLIF), and formaldehyde (CH _2 2 O) PLIF were …

High-speed volumetric imaging of formaldehyde in a lifted turbulent jet flame using an acousto-optic deflector

T Li, B Zhou, JH Frank, A Dreizler, B Böhm - Experiments in Fluids, 2020 - Springer
The development of high-speed volumetric laser-induced fluorescence measurements of
formaldehyde (CH _2 O CH 2 O-LIF) using a pulse-burst laser operated at a repetition rate of …

Measurement of local flame speeds in the thickened flamelet regime using simultaneous 10 kHz TPIV and OH/CH2O PLIF

J Osborne, SA Ramji, AM Steinberg… - 51st AIAA/SAE/ASEE …, 2015 - arc.aiaa.org
Simultaneous 10 kHz repetition-rate tomographic particle image velocimetry (TPIV), hydroxyl
planar laser induced fluorescence (OH PLIF), and formaldehyde (CH2O) PLIF were …

High-speed tomographic PIV and OH PLIF measurements in turbulent reactive flows

B Coriton, AM Steinberg, JH Frank - Experiments in fluids, 2014 - Springer
High-speed tomographic particle image velocimetry (TPIV) is demonstrated in turbulent
reactive flows at acquisition rates ranging from 10 to 16 kHz. The 10-kHz TPIV …

[PDF][PDF] Structure and dynamics of CH2O, OH, and the velocity field of a confined bluff-body premixed flame, using simultaneous PLIF and PIV at 10 kHz.

CA Fugger, S Roy, AW Caswell… - Proceedings of the …, 2019 - drive.google.com
This study characterizes the structure and dynamics of a confined, bluff-body-stabilized
turbulent premixed flame by simultaneously employing formaldehyde (CH2O) and hydroxyl …

Development of a three-legged, high-speed, burst-mode laser system for simultaneous measurements of velocity and scalars in reacting flows

S Roy, N Jiang, PS Hsu, T Yi, MN Slipchenko… - Optics Letters, 2018 - opg.optica.org
We report the development of a three-legged, high-speed, high-energy, burst-mode laser
system for the simultaneous measurement of velocity and key combustion species in …

Simultaneous measurements of velocity and CH distribution. Part II: deflected jet flames

D Han, MG Mungal - Combustion and Flame, 2003 - Elsevier
The mixing and combustion processes of deflected jet flames injected at three different
angles into a crossflow (− 45°, 0°, and 45°) are investigated using the simultaneous PIV and …

20  kHz CH2O and OH PLIF with stereo PIV

SD Hammack, CD Carter, AW Skiba, CA Fugger… - Optics letters, 2018 - opg.optica.org
Planar laser-induced fluorescence (PLIF) of hydroxyl (OH) and formaldehyde (CH_2O)
radicals was performed alongside stereo particle image velocimetry (PIV) at a 20 kHz …