CFD analysis of ejector in a combined ejector cooling system

E Rusly, L Aye, WWS Charters, A Ooi - International Journal of Refrigeration, 2005 - Elsevier
One-dimensional ejector analyses often use coefficients derived from experimental data for
a set of operating conditions with limited functionality. In this study, several ejector designs …

Investigation of ejectors in refrigeration system: Optimum performance evaluation and ejector area ratios perspectives

J Chen, H Havtun, B Palm - Applied Thermal Engineering, 2014 - Elsevier
This paper presents an ejector model to determine the optimum performance as well as
obtaining the design area ratio of an ejector in a refrigeration system. Working fluid …

CFD study of a variable area ratio ejector using R600a and R152a refrigerants

S Varga, PMS Lebre, AC Oliveira - International journal of refrigeration, 2013 - Elsevier
In the present paper, the numerical results for two 1 kW cooling capacity ejectors with
variable primary nozzle geometry are presented using R152a and R600a as working fluids …

A comprehensive review of ejector design, performance, and applications

BM Tashtoush, AN Moh'd A, MA Khasawneh - Applied Energy, 2019 - Elsevier
The objective of this work is to provide a literature survey on the research attempts made in
the field of ejector refrigeration systems and the studies made on the ejector as a …

A 1-D analysis of ejector performance

BJ Huang, JM Chang, CP Wang… - International journal of …, 1999 - Elsevier
A 1-D analysis for the prediction of ejector performance at critical-mode operation is carried
out in the present study. Constant-pressure mixing is assumed to occur inside the constant …

Parametric analysis of ejector working characteristics in the refrigeration system

J Chen, H Havtun, B Palm - Applied Thermal Engineering, 2014 - Elsevier
A detailed investigation of ejector working characteristics in terms of refrigeration efficiency,
ejector entrainment ratio, and irreversibilities in each ejector component (nozzle, mixing …

Analysis of an ejector with environment friendly refrigerants

A Selvaraju, A Mani - Applied Thermal Engineering, 2004 - Elsevier
When an ejector is operated at choking-mode, it gives a better performance with higher
entrainment ratio. To obtain this better performance at different operating conditions, area …

Maximum mass flow ratio due to secondary flow choking in an ejector refrigeration system

SK Chou, PR Yang, C Yap - International journal of refrigeration, 2001 - Elsevier
The occurrence of flow choking in an ejector of an ejector refrigeration system (ERS) was
analysed and a model for predicting the maximum flow ratio of the ejector was developed …

A 1D model to predict ejector performance at critical and sub-critical operational regimes

WX Chen, M Liu, DT Chong, JJ Yan, AB Little… - International journal of …, 2013 - Elsevier
This paper proposes a new 1D model to predict ejector performance at critical and sub-
critical operational modes, while most previous 1D models have only predicted ejector …

Empirical correlation for ejector design

BJ Huang, JM Chang - International journal of Refrigeration, 1999 - Elsevier
In the present study, two empirical correlations from the test results of 15 ejectors are derived
for the performance prediction of ejectors using R141b as the working fluid. The ratio of the …