Simulation of higher harmonics generation in tapping-mode atomic force microscopy

O Sahin, A Atalar - Applied Physics Letters, 2001 - pubs.aip.org
In tapping-mode atomic force microscopy, nonlinear tip–sample interactions give rise to
higher harmonics of the cantilever vibration. We present an electrical circuit to model the …

Higher-harmonics generation in tapping-mode atomic-force microscopy: Insights into the tip–sample interaction

R Hillenbrand, M Stark, R Guckenberger - Applied Physics Letters, 2000 - pubs.aip.org
We present an experimental analysis of the nonlinear tip–sample interaction in tapping-
mode atomic-force microscopy by exploiting anharmonic contributions of the cantilever …

Resonant harmonic response in tapping-mode atomic force microscopy

O Sahin, CF Quate, O Solgaard, A Atalar - Physical Review B, 2004 - APS
Higher harmonics in tapping-mode atomic force microscopy offers the potential for imaging
and sensing material properties at the nanoscale. The signal level at a given harmonic of the …

Spectroscopy of the anharmonic cantilever oscillations in tapping-mode atomic-force microscopy

M Stark, RW Stark, WM Heckl… - Applied Physics …, 2000 - pubs.aip.org
By spectroscopic analysis of the cantilever oscillation in tapping-mode atomic-force
microscopy (TM–AFM), we demonstrate that the transition from an oscillatory state …

Theory of higher harmonics imaging in tapping-mode atomic force microscopy

L Yuan, Q Jian-Qiang, L Ying-Zi - Chinese Physics B, 2010 - iopscience.iop.org
The periodic impact force induced by tip-sample contact in a tapping mode atomic force
microscope (AFM) gives rise to the non-harmonic response of a micro-cantilever. These non …

Higher harmonics imaging in tapping-mode atomic-force microscopy

RW Stark, WM Heckl - Review of Scientific Instruments, 2003 - pubs.aip.org
In tapping-mode atomic-force microscopy usually amplitude and phase of the cantilever
motion are acquired. These signals are related to the fundamental oscillation frequency …

Higher harmonics generation in tapping mode atomic force microscope

L Yuan, Q Jian-Qiang - Chinese Physics Letters, 2009 - iopscience.iop.org
The contribution of higher harmonics to the movement of a micro rectangular cantilever in
tapping mode AFM is investigated. The dependence between the phase lag of the higher …

Concentrated-mass cantilever enhances multiple harmonics in tapping-mode atomic force microscopy

H Li, Y Chen, L Dai - Applied Physics Letters, 2008 - pubs.aip.org
The natural frequencies of a cantilever probe can be tuned with an attached concentrated
mass to coincide with the higher harmonics generated in a tapping-mode atomic force …

Multi-frequency Atomic Force Microscopy based on enhanced internal resonance of an inner-paddled cantilever

R Potekin, S Dharmasena, H Keum, X Jiang… - Sensors and Actuators A …, 2018 - Elsevier
In this work, we study the performance of a new cantilever design during multi-frequency
tapping mode Atomic Force Microscopy (AFM). The system consists of a base cantilever with …

Enhancing higher harmonics of a tapping cantilever by excitation at a submultiple of its resonance frequency

M Balantekin, A Atalar - Physical Review B—Condensed Matter and Materials …, 2005 - APS
In a tapping-mode atomic force microscope, the frequency spectrum of the oscillating
cantilever contains higher harmonics at integer multiples of the excitation frequency. When …