Modelling the environment within a wet air-cooled vegetable store

SA Tassou, W Xiang - Journal of Food Engineering, 1998 - Elsevier
This paper presents a model for a wet air-cooled store based on computational fluid
dynamics. Unlike previous works on cold room modelling published in the literature, the …

Effects of design parameters on flow and temperature fields of a cold store by CFD simulation

J Xie, XH Qu, JY Shi, DW Sun - Journal of Food Engineering, 2006 - Elsevier
Recently, computational fluid dynamics (CFD) has been frequently applied in many fields
relating to fluid flow, and it has been shown that CFD is useful in these fields. The cooling …

Simplified heat transfer modeling in a cold room filled with food products

O Laguerre, S Duret, HM Hoang, L Guillier… - Journal of Food …, 2015 - Elsevier
High product and air temperatures and moistures are often observed in certain positions of a
cold room leading to deterioration of food quality and safety. To reduce food losses, it is …

Numerical modelling and experimental validation of a cold store ambient factors

S Akdemir, T Bartzanas - Journal of agricultural sciences, 2015 - dergipark.org.tr
The objective of this study was to analyse air temperature and relative humidity distribution
in an experimental cold store fully loaded with apples by using both experimental and …

Using advanced modelling techniques to reduce the cold spillage from retail display cabinets into supermarket stores to maintain customer comfort

AM Foster, GL Quarini - Proceedings of the Institution of …, 2001 - journals.sagepub.com
Chilled foods are increasingly popular on supermarket shelves. For marketing reasons,
chilled products are displayed in retail display cabinets where there is no physical barrier …

Steady state CFD modeling of airflow, heat transfer and moisture loss in a commercial potato cold store

MK Chourasia, TK Goswami - International Journal of Refrigeration, 2007 - Elsevier
Storage loss beyond permissible limit is one of the most important problems in Indian potato
cold stores, which has been hindering further growth of this industry. The losses in the stored …

The use of CFD to improve the performance of a partially loaded cold store

F Tanaka, Y Konishi, Y Kuroki… - Journal of Food …, 2012 - Wiley Online Library
ABSTRACT A transient three‐dimensional computational fluid dynamics model was
developed to investigate the cooling performance of a partially loaded cold store in cooling …

Experimental evaluation of cooling characteristic, airflow distribution and mass transfer in a cold store

R Bishnoi, KR Aharwal - Journal of Food Process Engineering, 2021 - Wiley Online Library
The cooling characteristics and safety of food products inside the cold room depend on the
temperature field and govern by the airflow distribution. The nonuniform air distribution …

CFD model of the airflow, heat and mass transfer in cool stores

HB Nahor, ML Hoang, P Verboven, M Baelmans… - International Journal of …, 2005 - Elsevier
A transient three-dimensional CFD model was developed to calculate the velocity,
temperature and moisture distribution in an existing empty and loaded cool store. The …

Mathematical modelling of heat transfer and water vapour transport in apple coolstores: a thesis presented in partial fulfilment of the requirements for the degree of …

ND Amos - 1995 - mro.massey.ac.nz
A study of heat transfer and water vapour transport in a large industrial apple coolstore was