Enhanced higher-harmonic imaging in tapping-mode atomic force microscopy

M Balantekin, A Atalar - Applied Physics Letters, 2005 - pubs.aip.org
Higher-harmonics generation in a tapping-mode atomic force microscope is a consequence
of the nonlinear tip-sample interaction force. The higher harmonics contain important …

Higher harmonics imaging in tapping-mode atomic-force microscopy

RW Stark, WM Heckl - Review of Scientific Instruments, 2003 - pubs.aip.org
In tapping-mode atomic-force microscopy usually amplitude and phase of the cantilever
motion are acquired. These signals are related to the fundamental oscillation frequency …

High harmonic exploring on different materials in dynamic atomic force microscopy

ZY Zheng, R Xu, SL Ye, S Hussain, W Ji… - Science China …, 2018 - Springer
In atomic force microscopy (AFM), high-frequency components consisted in dynamic tip-
sample interaction have been recently demonstrated as a promising technique for exploring …

Concentrated-mass cantilever enhances multiple harmonics in tapping-mode atomic force microscopy

H Li, Y Chen, L Dai - Applied Physics Letters, 2008 - pubs.aip.org
The natural frequencies of a cantilever probe can be tuned with an attached concentrated
mass to coincide with the higher harmonics generated in a tapping-mode atomic force …

Resonant harmonic response in tapping-mode atomic force microscopy

O Sahin, CF Quate, O Solgaard, A Atalar - Physical Review B, 2004 - APS
Higher harmonics in tapping-mode atomic force microscopy offers the potential for imaging
and sensing material properties at the nanoscale. The signal level at a given harmonic of the …

Higher harmonics and time-varying forces in dynamic force microscopy

O Sahin, CF Quate, O Solgaard, FJ Giessibl - Springer Handbook of …, 2010 - Springer
In atomic force microscopy, a force-sensing cantilever probes a sample and thereby creates
a topographic image of its surface. The simplest implementation uses the static deflection of …

Theory of higher harmonics imaging in tapping-mode atomic force microscopy

L Yuan, Q Jian-Qiang, L Ying-Zi - Chinese Physics B, 2010 - iopscience.iop.org
The periodic impact force induced by tip-sample contact in a tapping mode atomic force
microscope (AFM) gives rise to the non-harmonic response of a micro-cantilever. These non …

Wavelet analysis of higher harmonics in tapping mode atomic force microscopy

Z Wang, J Qian, Y Li, Y Zhang, Z Song, Z Dou, R Lin - Micron, 2019 - Elsevier
Higher harmonics have been widely used to characterize nanomechanical properties of the
sample surface in tapping mode atomic force microscopy. They are usually analyzed by the …

Simulation of higher harmonics generation in tapping-mode atomic force microscopy

O Sahin, A Atalar - Applied Physics Letters, 2001 - pubs.aip.org
In tapping-mode atomic force microscopy, nonlinear tip–sample interactions give rise to
higher harmonics of the cantilever vibration. We present an electrical circuit to model the …

[HTML][HTML] Unlocking higher harmonics in atomic force microscopy with gentle interactions

S Santos, V Barcons, J Font… - Beilstein journal of …, 2014 - beilstein-journals.org
In dynamic atomic force microscopy, nanoscale properties are encoded in the higher
harmonics. Nevertheless, when gentle interactions and minimal invasiveness are required …