Risk assessment of circuit breakers using influence diagrams with interval probabilities

JD Velimirovic, A Janjic - Symmetry, 2021 - mdpi.com
… the operation of a circuit breaker, as well as indicators of its condition, … Replacing the most
risky circuit breakers is a good basis for … the mechanism, as well as frequent visual inspection. …

Performance evaluation based on symptom, failed-type and obsolescence criteria of high voltage circuit breaker

T Suwanasri, C Suwanasri, S Nobnorp… - 2013 10th …, 2013 - ieeexplore.ieee.org
… For symptom criterion, weighting factors of 11 symptom aspects for HV circuit breaker such
as the visual inspection, diagnostic tests, failure frequency, deterioration of steel structure and …

Root cause analysis methodology for circuit breaker associated to GIS

RMA Velásquez, JVM Lara - Engineering Failure Analysis, 2020 - Elsevier
circuit breakers were caused by “Wear/Ageing”, according to the root cause analysis, the
visual … for detection of degradation for all types of circuit breakers, the ageing is 35 to 45 years. …

[PDF][PDF] Monitoring and Condition Assessment of High Voltage Circuit Breaker

T Owoeye - 2018 - livrepository.liverpool.ac.uk
… Such condition assessment needs to provide quality and reliability indicators for the circuit
breaker condition in order that network operators have confidence in its correct function. …

Automated monitoring and analysis of circuit breaker operation

M Kezunovic, Z Ren, G Latisko… - … on Power Delivery, 2005 - ieeexplore.ieee.org
… signals from the control circuitry is taken. The maintenance crew visually analyzes the record
… changes, CB mechanism actions and related waveform indications. Signals collected from …

Artificial intelligence SF6 circuit breaker health assessment

M Žarković, Z Stojković - Electric power systems research, 2019 - Elsevier
… of high voltage SF6 circuit breakers. Paper presents an … indicators of the state of high
voltage SF6 circuit breakers. Special attention is devoted to identifying and determining indicator

Maintenance and recurrent event analysis of circuit breaker data

D Bumblauskas, W Meeker, D Gemmill - International Journal of …, 2012 - emerald.com
Circuit breakers have gone through an evolution from the advent of the first oil circuit breaker
to today's SF 6 puffer style breaker… voltage classes, and all indications are that this trend will …

How to guarantee continuity of supply and reliability in the smart grids? diagnostic systems in the MV network components, circuit breakers and switch disconnectors

C Saeli, F Serpellini, C Gatti, A Bianco… - 2012 Petroleum and …, 2012 - ieeexplore.ieee.org
… way, the MV Circuit Breakers and Switch Disconnectors have … and displayed locally by
visual signaling in the Human … indication of the need for maintenance of the circuit breaker

Providing decision support for the condition-based maintenance of circuit breakers through data mining of trip coil current signatures

SM Strachan, SDJ McArthur, B Stephen… - … on Power Delivery, 2006 - ieeexplore.ieee.org
… into a more visually appreciable two-dimensional (2-D) representation [11]. The Sammon
map distribution of the plotted feature vectors offers a visual indication of the number of clusters …

Event timing and shape analysis of vibration bursts from power circuit breakers

AA Polycarpou, A Soom, V Swarnakar… - … on Power Delivery, 1996 - ieeexplore.ieee.org
… Presently, there is no condition yellow indicator defined for the first event value. … circuit
breaker operations. We have noted that in general, newer circuit breakers and circuit breakers