Extraction of effective parameters of turbid media utilizing the Mueller matrix approach: study of glucose sensing

TTH Pham, YL Lo - Journal of biomedical optics, 2012 - spiedigitallibrary.org
An analytical technique based on Stokes polarimetry and the Mueller matrix method is
proposed for extracting the effective linear birefringence, linear dichroism, circular …

Optical detection of glucose concentration in samples with scattering particles

LH Lin, YL Lo, CC Liao, JX Lin - Applied optics, 2015 - opg.optica.org
An optical-based method is proposed for measuring the glucose concentration of samples
containing scattering particles. In the proposed approach, a Stokes–Mueller reflection-based …

Differential Mueller matrix polarimetry technique for non-invasive measurement of glucose concentration on human fingertip

QH Phan, YL Lo - Optics Express, 2017 - opg.optica.org
A differential Mueller matrix polarimetry technique is proposed for obtaining non-invasive
(NI) measurements of the glucose concentration on the human fingertip. The feasibility of the …

Stokes–Mueller matrix polarimetry technique for circular dichroism/birefringence sensing with scattering effects

QH Phan, YL Lo - Journal of Biomedical Optics, 2017 - spiedigitallibrary.org
A surface plasmon resonance (SPR)-enhanced method is proposed for measuring the
circular dichroism (CD), circular birefringence (CB), and degree of polarization (DOP) of …

Mueller matrix decomposition for determination of optical rotation of glucose molecules in turbid media

P Sun, Y Ma, W Liu, Q Yang… - Journal of Biomedical …, 2014 - spiedigitallibrary.org
The optical activity of glucose molecules is important for diagnosing and monitoring blood
glucose of diabetes. In order to accurately detect the diabetes at an early stage, there is an …

Mueller matrix approach for determination of optical rotation in chiral turbid media in backscattering geometry

S Manhas, MK Swami, P Buddhiwant, N Ghosh… - Optics express, 2006 - opg.optica.org
For in vivo determination of optically active (chiral) substances in turbid media, like for
example glucose in human tissue, the backscattering geometry is particularly convenient …

Glucose sensing in the presence of scattering by analyzing a partial Mueller matrix

P Mukherjee, N Hagen, Y Otani - Optik, 2019 - Elsevier
We propose a method to analyze a partial Mueller matrix to retrieve the optical rotation and
depolarization properties simultaneously for measuring glucose concentration in the …

Polarized Mueller matrix analytical model for glucose measurement in vitro

S Firdous, M Ikram - Turkish Journal of Medical Sciences, 2005 - journals.tubitak.gov.tr
In this study we present a noninvasive and nonradioactive glucose in vitro measurement
technique using the Mueller polarization analytical model. The glucose solution and …

Optical parameters of human blood plasma, collagen, and calfskin based on the Stokes–Mueller technique

HTT Pham, ALT Nguyen, TV Vo, KC Huynh… - Applied optics, 2018 - opg.optica.org
A decoupled analytical technique based on the Stokes–Mueller matrix decomposition
method extracts polarization properties of human blood plasma, collagen solution, and …

Multispectral polarimetric system for glucose monitoring

GL Cote, H Gorde, J Janda… - Biomedical Sensing and …, 1998 - spiedigitallibrary.org
In this preliminary investigation, a two wavelength optical polarimetric system was used to
show the potential of the approach to be used as an in vivo noninvasive glucose monitor …