The use of interfragmentary positional screw in minimally invasive plate osteosynthesis for simple distal femur fractures in elderly patients: A retrospective, single …

JY Chung, JH Cho, HJ Kweon, HK Song - Injury, 2016 - Elsevier
Introduction Minimally invasive plate osteosynthesis (MIPO) using locking plates has been
used in distal femur fractures, but various problems, such as nonunion, malalignment, and …

Clinical outcomes of distal femoral fractures in the geriatric population using locking plates with a minimally invasive approach

HK Doshi, P Wenxian, MV Burgula… - … orthopaedic surgery & …, 2013 - journals.sagepub.com
Background: Fractures of the distal femur comprise 4% to 6% of all femoral fractures. Elderly
patients are predisposed to low-energy fractures due to osteoporosis. Treatment of these …

Surgical outcomes of simple distal femur fractures in elderly patients treated with the minimally invasive plate osteosynthesis technique: can percutaneous cerclage …

JH Lee, KC Park, SJ Lim, KB Kwon, JW Kim - Archives of orthopaedic and …, 2020 - Springer
Introduction Achieving adequate reduction is difficult when performing minimally invasive
plate osteosynthesis (MIPO) in elderly patients with simple distal femur fracture. This study …

Minimally invasive plate osteosynthesis using a locking compression plate for distal femoral fractures

RM Nayak, RMR Koichade… - Journal of …, 2011 - journals.sagepub.com
Purpose. To evaluate treatment outcomes of minimally invasive plate osteosynthesis (MIPO)
for distal femoral fractures in 31 patients. Methods. 22 male and 9 female consecutive …

[HTML][HTML] Outcomes of distal femoral fractures treated with minimally invasive plate osteosynthesis versus open reduction internal fixation with combined locking plate …

SH Wang, CC Wu, WT Li, HC Shen, LC Lin… - International Journal of …, 2019 - Elsevier
Purpose Fractures of the distal femur remain challenging to treat, and numerous fixation
methods are designed to promote stability and fracture healing. Locking plate constructs …

Treatment of distal femur fracture with minimally invasive locking compression plate osteosynthesis

KC Park, KS Chung, JK Moon - Journal of the Korean …, 2012 - synapse.koreamed.org
Purpose To analyze the result of distal femur fracture treatment with minimally invasive plate
osteosynthesis (MIPO) using a locking compression plate (LCP). Materials and Methods …

Overlapping intramedullary nailing after failed minimally invasive locked plating for osteoporotic distal femur fractures–Report of 2 cases

JH Yoo, SW Kim, YH Kwak, HJ Kim - Injury, 2015 - Elsevier
Minimally invasive plate osteosynthesis (MIPO) using a locking plate has been widely used
for distal femur fractures in the elderly with osteoporosis and yielded favourable results …

Using a traction table for fracture reduction during minimally invasive plate osteosynthesis (MIPO) of distal femoral fractures provides anatomical alignment

M Paulsson, C Ekholm, R Tranberg, O Rolfson… - Journal of Clinical …, 2023 - mdpi.com
Introduction: Fracture reduction and fixation of distal femur fractures are technically
demanding. Postoperative malalignment is still commonly reported after minimally invasive …

Minimally invasive plate osteosynthesis (MIPO) in the treatment of the femoral shaft fracture where intramedullary nailing is not indicated

T Apivatthakakul, S Chiewcharntanakit - International orthopaedics, 2009 - Springer
The aim of this study was to examine the results of minimally invasive plate osteosynthesis
(MIPO) of the femoral shaft fracture in patients where intramedullary nailing is …

Comparison of results of minimally invasive plate osteosynthesis according to types of locking plate in distal femoral fractures

OJ Shon, MS Kwon, CH Park - Journal of the Korean …, 2012 - synapse.koreamed.org
Purpose To compare results of minimally invasive plate osteosynthesis using a locking
compression plate and a periarticular locking plate in distal femur fractures. Materials and …