Experimental validation of a direct pre-design formula for TLCD

A Di Matteo, FL Iacono, G Navarra, A Pirrotta - Engineering Structures, 2014 - Elsevier
The passive control of vibrations has received in recent years a great deal of attention from
researchers. Several types of devices have been proposed in order to reduce the dynamic …

Performance of tuned liquid column dampers considering maximum liquid motion in seismic vibration control of structures

S Chakraborty, R Debbarma, GC Marano - Journal of Sound and Vibration, 2012 - Elsevier
The optimum design of tuned liquid column damper (TLCD) is usually performed by
minimizing the maximum response of structure subjected to stochastic earthquake load …

Optimal tuned inerter dampers for vibration control performance of adjacent building structures

X Kang, J Tang, F Li, J Wu, J Wei, Q Huang, Z Li… - Buildings, 2023 - mdpi.com
Under the effect of strong earthquakes, collisions or excessive inter-story displacements may
occur between adjacent building structures to the extent that the building structure is …

Application of tuned liquid column ball damper (TLCBD) for improved vibration control performance of multi-storey structure

M Tanveer, M Usman, IU Khan, S Ahmad, A Hanif… - PLoS …, 2019 - journals.plos.org
Tuned liquid column ball damper (TLCBD) is a passive control device used for controlling
the building vibrations induced from wind or earthquakes. TLCBD is a modified form of …

Tuned liquid column damper for structural control

MJ Hochrainer - Acta Mechanica, 2005 - Springer
Tuned liquid column dampers (TLCDs) are energy dissipating substructures, which can be
used to improve the dynamics of structures. The basic operating principle is an energy …

[HTML][HTML] Point to point time optimal handling of unmounted rigid objects and liquid-filled containers

H Gattringer, A Müller, S Weitzhofer… - … and Machine Theory, 2023 - Elsevier
Time optimal handling of parts loosely placed at the end-effector (EE) of a robot, known as
waiter motion problem, has high practical relevance, which becomes more challenging if the …

Tuned liquid column ball damper for seismic vibration control

S Gur, K Roy, SK Mishra - Structural Control and Health …, 2015 - Wiley Online Library
Tuned liquid column damper (TLCD) is a passive control device for vibration control of
structures. Recently, the tuned liquid column ball damper (TLCBD) has been introduced for …

Seismic responses of an offshore jacket-type platform incorporated with tuned liquid dampers

MA Lotfollahi-Yaghin, H Ahmadi… - Advances in Structural …, 2016 - journals.sagepub.com
In this article, the efficiency of tuned liquid damper in controlling the dynamic responses of
offshore jacket-type platforms under earthquake excitation is investigated. This type of …

Wind-induced vibration control of long span cable-stayed bridges using multiple pressurized tuned liquid column dampers

KM Shum, YL Xu, WH Guo - Journal of wind engineering and industrial …, 2008 - Elsevier
This paper explores the possibility of using multiple pressurized tuned liquid column damper
(MPTLCD) to reduce wind-induced vibration of long span cable-stayed bridges. By …

Combining TMD and TLCD: analytical and experimental studies

A Di Matteo, A Pirrotta, S Tumminelli - Journal of Wind Engineering and …, 2017 - Elsevier
In these years several research efforts have been focused on developing efficient and
reliable control devices for mitigating the structural response of tall and lightly damped …