Automated analysis of intima‐media thickness: analysis and performance of CARES 3.0

L Saba, R Montisci, L Famiglietti… - … of Ultrasound in …, 2013 - Wiley Online Library
Objectives In recent years, the use of computer‐based techniques has been advocated to
improve intima‐media thickness (IMT) quantification and its reproducibility. The purpose of …

A systematic review of conventional and deep learning models for the measurement of plaque burden

M Biswas, JS Suri - Multimodality Imaging, Volume 1: Deep …, 2022 - iopscience.iop.org
A systematic review of conventional and deep learning models for the measurement of plaque
burden - Book chapter - IOPscience This site uses cookies. By continuing to use this site you …

CARES 2.0: completely automated robust edge snapper for CIMT measurement in 300 ultrasound images—a two stage paradigm

F Molinari, RU Acharya, G Zeng… - Journal of Medical …, 2011 - ingentaconnect.com
The carotid intima-media thickness (IMT) is a widely used marker associated to the risk of
cardiovascular diseases and to atherosclerosis progression. IMT measurement requires …

Automatic evaluation of carotid intima-media thickness in ultrasounds using machine learning

RM Menchón-Lara, MC Bastida-Jumilla… - Natural and Artificial …, 2013 - Springer
Cardiovascular diseases (CVD) are the main cause of death and disability in the world.
Atherosclerosis is responsible for a large proportion of cardiovascular diseases. The …

Using two methods for recognition common carotid artery of B-mode longitudinal ultrasound image

J Wan, Q Ruan, W Li - IEEE 10th INTERNATIONAL …, 2010 - ieeexplore.ieee.org
In this paper two novel methods are proposed for recognizing B-mode ultrasound (US)
imaging of common carotid artery (CCA) in longitude. In the single frame method, the US is …

A review on artery wall segmentation techniques and intima-media thickness measurement for carotid ultrasound images

X Yang, W He, K Li, J Jin, X Zhang… - Journal of Innovative …, 2012 - World Scientific
Stroke and heart attack, which could be led by a kind of cerebrovascular and cardiovascular
disease named as atherosclerosis, would seriously cause human morbidity and mortality. It …

CARES: Completely Automated Robust Edge Snapper for carotid ultrasound IMT measurement on a multi-institutional database of 300 images: a two stage system …

F Molinari, R Acharya, G Zeng… - Medical Imaging 2011 …, 2011 - spiedigitallibrary.org
The carotid intima-media thickness (IMT) is the most used marker for the progression of
atherosclerosis and onset of the cardiovascular diseases. Computer-aided measurements …

Inter-Greedy technique for fusion of different carotid segmentation boundaries leading to high-performance IMT measurement

F Molinari, G Zeng, JS Suri - 2010 Annual International …, 2010 - ieeexplore.ieee.org
User-based estimation of intima-media thickness (IMT) of carotid arteries leads to
subjectivity in its decision support systems, while being used as a cardiovascular risk …

Region growing based on window frame difference for segmenting ultrasonic contrast images of arteries

B Jiang, M Qian, L Niu, R Song, H Zhu… - 2011 5th …, 2011 - ieeexplore.ieee.org
The arterial wall position has impacts on the accuracy of wall shear stress calculation. In this
paper, a novel region growing algorithm based on window frame difference is proposed for …

Automated IMT Carotid Artery Far Wall Segmentation Techniques

KM Meiburger, KM Meiburger - … Imaging for the Assessment of Vascular …, 2017 - Springer
This Chapter focuses on the development and validation of quantitative techniques for the
assessment of vascular morphological parameters that can be extracted from B-mode …